Modbus - Hall Effect Bricklet 2.0

This is the description of the Modbus protocol for the Hall Effect Bricklet 2.0. General information and technical specifications for the Hall Effect Bricklet 2.0 are summarized in its hardware description.

API

A general description of the Modbus protocol structure can be found here.

Basic Functions

BrickletHallEffectV2.get_magnetic_flux_density
Function ID:
  • 1
Request:
  • empty payload
Response:
  • magnetic_flux_density – Type: int16, Unit: 1 µT, Range: [-7000 to 7000]

Returns the magnetic flux density (magnetic induction).

If you want to get the value periodically, it is recommended to use the CALLBACK_MAGNETIC_FLUX_DENSITY callback. You can set the callback configuration with set_magnetic_flux_density_callback_configuration.

BrickletHallEffectV2.get_counter
Function ID:
  • 5
Request:
  • reset_counter – Type: bool
Response:
  • count – Type: uint32, Range: [0 to 232 - 1]

Returns the current value of the counter.

You can configure the low/high thresholds and the debounce time with set_counter_config.

If you set reset counter to true, the count is set back to 0 directly after it is read.

If you want to get the count periodically, it is recommended to use the CALLBACK_COUNTER callback. You can set the callback configuration with set_counter_callback_configuration.

BrickletHallEffectV2.set_counter_config
Function ID:
  • 6
Request:
  • high_threshold – Type: int16, Unit: 1 µT, Range: [-215 to 215 - 1], Default: 2000
  • low_threshold – Type: int16, Unit: 1 µT, Range: [-215 to 215 - 1], Default: -2000
  • debounce – Type: uint32, Unit: 1 µs, Range: [0 to 1000000], Default: 100000
Response:
  • no response

Sets a high and a low threshold as well as a debounce time.

If the measured magnetic flux density goes above the high threshold or below the low threshold, the count of the counter is increased by 1.

The debounce time is the minimum time between two count increments.

BrickletHallEffectV2.get_counter_config
Function ID:
  • 7
Request:
  • empty payload
Response:
  • high_threshold – Type: int16, Unit: 1 µT, Range: [-215 to 215 - 1], Default: 2000
  • low_threshold – Type: int16, Unit: 1 µT, Range: [-215 to 215 - 1], Default: -2000
  • debounce – Type: uint32, Unit: 1 µs, Range: [0 to 1000000], Default: 100000

Returns the counter config as set by set_counter_config.

Advanced Functions

BrickletHallEffectV2.get_spitfp_error_count
Function ID:
  • 234
Request:
  • empty payload
Response:
  • error_count_ack_checksum – Type: uint32, Range: [0 to 232 - 1]
  • error_count_message_checksum – Type: uint32, Range: [0 to 232 - 1]
  • error_count_frame – Type: uint32, Range: [0 to 232 - 1]
  • error_count_overflow – Type: uint32, Range: [0 to 232 - 1]

Returns the error count for the communication between Brick and Bricklet.

The errors are divided into

  • ACK checksum errors,
  • message checksum errors,
  • framing errors and
  • overflow errors.

The errors counts are for errors that occur on the Bricklet side. All Bricks have a similar function that returns the errors on the Brick side.

BrickletHallEffectV2.set_status_led_config
Function ID:
  • 239
Request:
  • config – Type: uint8, Range: See meanings, Default: 3
Response:
  • no response

Sets the status LED configuration. By default the LED shows communication traffic between Brick and Bricklet, it flickers once for every 10 received data packets.

You can also turn the LED permanently on/off or show a heartbeat.

If the Bricklet is in bootloader mode, the LED is will show heartbeat by default.

The following meanings are defined for the elements of this function:

For config:

  • 0 = Off
  • 1 = On
  • 2 = Show Heartbeat
  • 3 = Show Status
BrickletHallEffectV2.get_status_led_config
Function ID:
  • 240
Request:
  • empty payload
Response:
  • config – Type: uint8, Range: See meanings, Default: 3

Returns the configuration as set by set_status_led_config

The following meanings are defined for the elements of this function:

For config:

  • 0 = Off
  • 1 = On
  • 2 = Show Heartbeat
  • 3 = Show Status
BrickletHallEffectV2.get_chip_temperature
Function ID:
  • 242
Request:
  • empty payload
Response:
  • temperature – Type: int16, Unit: 1 °C, Range: [-215 to 215 - 1]

Returns the temperature as measured inside the microcontroller. The value returned is not the ambient temperature!

The temperature is only proportional to the real temperature and it has bad accuracy. Practically it is only useful as an indicator for temperature changes.

BrickletHallEffectV2.reset
Function ID:
  • 243
Request:
  • empty payload
Response:
  • no response

Calling this function will reset the Bricklet. All configurations will be lost.

After a reset you have to create new device objects, calling functions on the existing ones will result in undefined behavior!

BrickletHallEffectV2.get_identity
Function ID:
  • 255
Request:
  • empty payload
Response:
  • uid – Type: char[8]
  • connected_uid – Type: char[8]
  • position – Type: char, Range: ['a' to 'h', 'z']
  • hardware_version – Type: uint8[3]
    • 0: major – Type: uint8, Range: [0 to 255]
    • 1: minor – Type: uint8, Range: [0 to 255]
    • 2: revision – Type: uint8, Range: [0 to 255]
  • firmware_version – Type: uint8[3]
    • 0: major – Type: uint8, Range: [0 to 255]
    • 1: minor – Type: uint8, Range: [0 to 255]
    • 2: revision – Type: uint8, Range: [0 to 255]
  • device_identifier – Type: uint16, Range: [0 to 216 - 1]

Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.

The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an Isolator Bricklet is always at position 'z'.

The device identifier numbers can be found here

Callback Configuration Functions

BrickletHallEffectV2.set_magnetic_flux_density_callback_configuration
Function ID:
  • 2
Request:
  • period – Type: uint32, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • value_has_to_change – Type: bool, Default: false
  • option – Type: char, Range: See meanings, Default: 'x'
  • min – Type: int16, Unit: 1 µT, Range: [-215 to 215 - 1], Default: 0
  • max – Type: int16, Unit: 1 µT, Range: [-215 to 215 - 1], Default: 0
Response:
  • no response

The period is the period with which the CALLBACK_MAGNETIC_FLUX_DENSITY callback is triggered periodically. A value of 0 turns the callback off.

If the value has to change-parameter is set to true, the callback is only triggered after the value has changed. If the value didn't change within the period, the callback is triggered immediately on change.

If it is set to false, the callback is continuously triggered with the period, independent of the value.

It is furthermore possible to constrain the callback with thresholds.

The option-parameter together with min/max sets a threshold for the CALLBACK_MAGNETIC_FLUX_DENSITY callback.

The following options are possible:

Option Description
'x' Threshold is turned off
'o' Threshold is triggered when the value is outside the min and max values
'i' Threshold is triggered when the value is inside or equal to the min and max values
'<' Threshold is triggered when the value is smaller than the min value (max is ignored)
'>' Threshold is triggered when the value is greater than the min value (max is ignored)

If the option is set to 'x' (threshold turned off) the callback is triggered with the fixed period.

The following meanings are defined for the elements of this function:

For option:

  • 'x' = Off
  • 'o' = Outside
  • 'i' = Inside
  • '<' = Smaller
  • '>' = Greater
BrickletHallEffectV2.get_magnetic_flux_density_callback_configuration
Function ID:
  • 3
Request:
  • empty payload
Response:
  • period – Type: uint32, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • value_has_to_change – Type: bool, Default: false
  • option – Type: char, Range: See meanings, Default: 'x'
  • min – Type: int16, Unit: 1 µT, Range: [-215 to 215 - 1], Default: 0
  • max – Type: int16, Unit: 1 µT, Range: [-215 to 215 - 1], Default: 0

Returns the callback configuration as set by set_magnetic_flux_density_callback_configuration.

The following meanings are defined for the elements of this function:

For option:

  • 'x' = Off
  • 'o' = Outside
  • 'i' = Inside
  • '<' = Smaller
  • '>' = Greater
BrickletHallEffectV2.set_counter_callback_configuration
Function ID:
  • 8
Request:
  • period – Type: uint32, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • value_has_to_change – Type: bool, Default: false
Response:
  • no response

The period is the period with which the CALLBACK_COUNTER callback is triggered periodically. A value of 0 turns the callback off.

If the value has to change-parameter is set to true, the callback is only triggered after at least one of the values has changed. If the values didn't change within the period, the callback is triggered immediately on change.

If it is set to false, the callback is continuously triggered with the period, independent of the value.

BrickletHallEffectV2.get_counter_callback_configuration
Function ID:
  • 9
Request:
  • empty payload
Response:
  • period – Type: uint32, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • value_has_to_change – Type: bool, Default: false

Returns the callback configuration as set by set_counter_callback_configuration.

Callbacks

BrickletHallEffectV2.CALLBACK_MAGNETIC_FLUX_DENSITY
Function ID:
  • 4
Response:
  • magnetic_flux_density – Type: int16, Unit: 1 µT, Range: [-7000 to 7000]

This callback is triggered periodically according to the configuration set by set_magnetic_flux_density_callback_configuration.

The response value is the same as get_magnetic_flux_density.

BrickletHallEffectV2.CALLBACK_COUNTER
Function ID:
  • 10
Response:
  • count – Type: uint32, Range: [0 to 232 - 1]

This callback is triggered periodically according to the configuration set by set_counter_callback_configuration.

The count is the same as you would get with get_counter.

Internal Functions

Internal functions are used for maintenance tasks such as flashing a new firmware of changing the UID of a Bricklet. These task should be performed using Brick Viewer instead of using the internal functions directly.

BrickletHallEffectV2.set_bootloader_mode
Function ID:
  • 235
Request:
  • mode – Type: uint8, Range: See meanings
Response:
  • status – Type: uint8, Range: See meanings

Sets the bootloader mode and returns the status after the requested mode change was instigated.

You can change from bootloader mode to firmware mode and vice versa. A change from bootloader mode to firmware mode will only take place if the entry function, device identifier and CRC are present and correct.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

The following meanings are defined for the elements of this function:

For mode:

  • 0 = Bootloader
  • 1 = Firmware
  • 2 = Bootloader Wait For Reboot
  • 3 = Firmware Wait For Reboot
  • 4 = Firmware Wait For Erase And Reboot

For status:

  • 0 = OK
  • 1 = Invalid Mode
  • 2 = No Change
  • 3 = Entry Function Not Present
  • 4 = Device Identifier Incorrect
  • 5 = CRC Mismatch
BrickletHallEffectV2.get_bootloader_mode
Function ID:
  • 236
Request:
  • empty payload
Response:
  • mode – Type: uint8, Range: See meanings

Returns the current bootloader mode, see set_bootloader_mode.

The following meanings are defined for the elements of this function:

For mode:

  • 0 = Bootloader
  • 1 = Firmware
  • 2 = Bootloader Wait For Reboot
  • 3 = Firmware Wait For Reboot
  • 4 = Firmware Wait For Erase And Reboot
BrickletHallEffectV2.set_write_firmware_pointer
Function ID:
  • 237
Request:
  • pointer – Type: uint32, Unit: 1 B, Range: [0 to 232 - 1]
Response:
  • no response

Sets the firmware pointer for write_firmware. The pointer has to be increased by chunks of size 64. The data is written to flash every 4 chunks (which equals to one page of size 256).

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

BrickletHallEffectV2.write_firmware
Function ID:
  • 238
Request:
  • data – Type: uint8[64], Range: [0 to 255]
Response:
  • status – Type: uint8, Range: [0 to 255]

Writes 64 Bytes of firmware at the position as written by set_write_firmware_pointer before. The firmware is written to flash every 4 chunks.

You can only write firmware in bootloader mode.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

BrickletHallEffectV2.write_uid
Function ID:
  • 248
Request:
  • uid – Type: uint32, Range: [0 to 232 - 1]
Response:
  • no response

Writes a new UID into flash. If you want to set a new UID you have to decode the Base58 encoded UID string into an integer first.

We recommend that you use Brick Viewer to change the UID.

BrickletHallEffectV2.read_uid
Function ID:
  • 249
Request:
  • empty payload
Response:
  • uid – Type: uint32, Range: [0 to 232 - 1]

Returns the current UID as an integer. Encode as Base58 to get the usual string version.