Modbus - Analog Out Bricklet 2.0
This is the description of the Modbus protocol for the Analog Out Bricklet 2.0. General information and technical
specifications for the Analog Out Bricklet 2.0 are summarized in its hardware description.
API
A general description of the Modbus protocol structure can be found
here.
Basic Functions
-
BrickletAnalogOutV2.set_output_voltage
| Function ID: | |
| Request: | - voltage – Type: uint16, Unit: 1 mV, Range: [0 to 12000], Default: 0
|
| Response: | |
Sets the voltage.
-
BrickletAnalogOutV2.get_output_voltage
| Function ID: | |
| Request: | |
| Response: | - voltage – Type: uint16, Unit: 1 mV, Range: [0 to 12000], Default: 0
|
Returns the voltage as set by set_output_voltage.
Advanced Functions
-
BrickletAnalogOutV2.get_input_voltage
| Function ID: | |
| Request: | |
| Response: | - voltage – Type: uint16, Unit: 1 mV, Range: [0 to 15000]
|
Returns the input voltage.
-
BrickletAnalogOutV2.get_identity
| Function ID: | |
| Request: | |
| Response: | - uid – Type: char[8]
- connected_uid – Type: char[8]
- position – Type: char, Range: ['a' to 'h', 'z']
- hardware_version – Type: uint8[3]
- 0: major – Type: uint8, Range: [0 to 255]
- 1: minor – Type: uint8, Range: [0 to 255]
- 2: revision – Type: uint8, Range: [0 to 255]
- firmware_version – Type: uint8[3]
- 0: major – Type: uint8, Range: [0 to 255]
- 1: minor – Type: uint8, Range: [0 to 255]
- 2: revision – Type: uint8, Range: [0 to 255]
- device_identifier – Type: uint16, Range: [0 to 216 - 1]
|
Returns the UID, the UID where the Bricklet is connected to,
the position, the hardware and firmware version as well as the
device identifier.
The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port).
A Bricklet connected to an Isolator Bricklet is always at
position 'z'.
The device identifier numbers can be found here.