MATLAB/Octave - Stepper Brick

This is the description of the MATLAB/Octave API bindings for the Stepper Brick. General information and technical specifications for the Stepper Brick are summarized in its hardware description.

An installation guide for the MATLAB/Octave API bindings is part of their general description.

Examples

The example code below is Public Domain (CC0 1.0).

Configuration (MATLAB)

Download (matlab_example_configuration.m)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
function matlab_example_configuration()
    import com.tinkerforge.IPConnection;
    import com.tinkerforge.BrickStepper;

    HOST = 'localhost';
    PORT = 4223;
    UID = 'XXYYZZ'; % Change XXYYZZ to the UID of your Stepper Brick

    ipcon = IPConnection(); % Create IP connection
    stepper = handle(BrickStepper(UID, ipcon), 'CallbackProperties'); % Create device object

    ipcon.connect(HOST, PORT); % Connect to brickd
    % Don't use device before ipcon is connected

    stepper.setMotorCurrent(800); % 800 mA
    stepper.setStepMode(8); % 1/8 step mode
    stepper.setMaxVelocity(2000); % Velocity 2000 steps/s

    % Slow acceleration (500 steps/s^2),
    % Fast deacceleration (5000 steps/s^2)
    stepper.setSpeedRamping(500, 5000);

    stepper.enable(); % Enable motor power
    stepper.setSteps(60000); % Drive 60000 steps forward

    input('Press key to exit\n', 's');

    % Stop motor before disabling motor power
    stepper.stop(); % Request motor stop
    stepper.setSpeedRamping(500, ...
                            5000); % Fast deacceleration (5000 steps/s^2) for stopping
    pause(0.4); % Wait for motor to actually stop: max velocity (2000 steps/s) / decceleration (5000 steps/s^2) = 0.4 s
    stepper.disable(); % Disable motor power

    ipcon.disconnect();
end

Callback (MATLAB)

Download (matlab_example_callback.m)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
function matlab_example_callback()
    import com.tinkerforge.IPConnection;
    import com.tinkerforge.BrickStepper;

    HOST = 'localhost';
    PORT = 4223;
    UID = 'XXYYZZ'; % Change XXYYZZ to the UID of your Stepper Brick

    ipcon = IPConnection(); % Create IP connection
    stepper = handle(BrickStepper(UID, ipcon), 'CallbackProperties'); % Create device object

    ipcon.connect(HOST, PORT); % Connect to brickd
    % Don't use device before ipcon is connected

    % Register position reached callback to function cb_position_reached
    set(stepper, 'PositionReachedCallback', @(h, e) cb_position_reached(e));

    stepper.enable(); % Enable motor power
    stepper.setSteps(1); % Drive one step forward to get things going

    input('Press key to exit\n', 's');

    % Stop motor before disabling motor power
    stepper.stop(); % Request motor stop
    stepper.setSpeedRamping(500, ...
                            5000); % Fast deacceleration (5000 steps/s^2) for stopping
    pause(0.4); % Wait for motor to actually stop: max velocity (2000 steps/s) / decceleration (5000 steps/s^2) = 0.4 s
    stepper.disable(); % Disable motor power

    ipcon.disconnect();
end

% Use position reached callback to program random movement
function cb_position_reached(e)
    stepper = e.getSource();

    if randi([0, 1])
        steps = randi([1000, 5000]); % steps (forward);
        fprintf('Driving forward: %g steps\n', steps);
    else
        steps = randi([-5000, -1000]); % steps (backward);
        fprintf('Driving backward: %g steps\n', steps);
    end

    vel = randi([200, 2000]); % steps/s
    acc = randi([100, 1000]); % steps/s^2
    dec = randi([100, 1000]); % steps/s^2
    fprintf('Configuration (vel, acc, dec): %g, %g, %g\n', vel, acc, dec);

    stepper.setSpeedRamping(acc, dec);
    stepper.setMaxVelocity(vel);
    stepper.setSteps(steps);
end

Configuration (Octave)

Download (octave_example_configuration.m)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
function octave_example_configuration()
    more off;

    HOST = "localhost";
    PORT = 4223;
    UID = "XXYYZZ"; % Change XXYYZZ to the UID of your Stepper Brick

    ipcon = javaObject("com.tinkerforge.IPConnection"); % Create IP connection
    stepper = javaObject("com.tinkerforge.BrickStepper", UID, ipcon); % Create device object

    ipcon.connect(HOST, PORT); % Connect to brickd
    % Don't use device before ipcon is connected

    stepper.setMotorCurrent(800); % 800 mA
    stepper.setStepMode(8); % 1/8 step mode
    stepper.setMaxVelocity(2000); % Velocity 2000 steps/s

    % Slow acceleration (500 steps/s^2),
    % Fast deacceleration (5000 steps/s^2)
    stepper.setSpeedRamping(500, 5000);

    stepper.enable(); % Enable motor power
    stepper.setSteps(60000); % Drive 60000 steps forward

    input("Press key to exit\n", "s");

    % Stop motor before disabling motor power
    stepper.stop(); % Request motor stop
    stepper.setSpeedRamping(500, ...
                            5000); % Fast deacceleration (5000 steps/s^2) for stopping
    pause(0.4); % Wait for motor to actually stop: max velocity (2000 steps/s) / decceleration (5000 steps/s^2) = 0.4 s
    stepper.disable(); % Disable motor power

    ipcon.disconnect();
end

Callback (Octave)

Download (octave_example_callback.m)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
function octave_example_callback()
    more off;

    HOST = "localhost";
    PORT = 4223;
    UID = "XXYYZZ"; % Change XXYYZZ to the UID of your Stepper Brick

    ipcon = javaObject("com.tinkerforge.IPConnection"); % Create IP connection
    stepper = javaObject("com.tinkerforge.BrickStepper", UID, ipcon); % Create device object

    ipcon.connect(HOST, PORT); % Connect to brickd
    % Don't use device before ipcon is connected

    % Register position reached callback to function cb_position_reached
    stepper.addPositionReachedCallback(@cb_position_reached);

    stepper.enable(); % Enable motor power
    stepper.setSteps(1); % Drive one step forward to get things going

    input("Press key to exit\n", "s");

    % Stop motor before disabling motor power
    stepper.stop(); % Request motor stop
    stepper.setSpeedRamping(500, ...
                            5000); % Fast deacceleration (5000 steps/s^2) for stopping
    pause(0.4); % Wait for motor to actually stop: max velocity (2000 steps/s) / decceleration (5000 steps/s^2) = 0.4 s
    stepper.disable(); % Disable motor power

    ipcon.disconnect();
end

% Use position reached callback to program random movement
function cb_position_reached(e)
    stepper = e.getSource();

    if randi([0, 1])
        steps = randi([1000, 5000]); % steps (forward);
        fprintf("Driving forward: %g steps\n", steps);
    else
        steps = randi([-5000, -1000]); % steps (backward);
        fprintf("Driving backward: %g steps\n", steps);
    end

    vel = randi([200, 2000]); % steps/s
    acc = randi([100, 1000]); % steps/s^2
    dec = randi([100, 1000]); % steps/s^2
    fprintf("Configuration (vel, acc, dec): %g, %g, %g\n", vel, acc, dec);

    stepper.setSpeedRamping(acc, dec);
    stepper.setMaxVelocity(vel);
    stepper.setSteps(steps);
end

API

Generally, every method of the MATLAB bindings that returns a value can throw a TimeoutException. This exception gets thrown if the device did not respond. If a cable based connection is used, it is unlikely that this exception gets thrown (assuming nobody unplugs the device). However, if a wireless connection is used, timeouts will occur if the distance to the device gets too big.

Beside the TimeoutException there is also a NotConnectedException that is thrown if a method needs to communicate with the device while the IP Connection is not connected.

Since the MATLAB bindings are based on Java and Java does not support multiple return values and return by reference is not possible for primitive types, we use small classes that only consist of member variables. The member variables of the returned objects are described in the corresponding method descriptions.

The package for all Brick/Bricklet bindings and the IP Connection is com.tinkerforge.*

All methods listed below are thread-safe.

Basic Functions

class BrickStepper(String uid, IPConnection ipcon)
Parameters:
  • uid – Type: String
  • ipcon – Type: IPConnection
Returns:
  • stepper – Type: BrickStepper

Creates an object with the unique device ID uid.

In MATLAB:

import com.tinkerforge.BrickStepper;

stepper = BrickStepper('YOUR_DEVICE_UID', ipcon);

In Octave:

stepper = java_new("com.tinkerforge.BrickStepper", "YOUR_DEVICE_UID", ipcon);

This object can then be used after the IP Connection is connected.

void BrickStepper.setMaxVelocity(int velocity)
Parameters:
  • velocity – Type: int, Unit: 1 1/s, Range: [0 to 216 - 1]

Sets the maximum velocity of the stepper motor. This function does not start the motor, it merely sets the maximum velocity the stepper motor is accelerated to. To get the motor running use either setTargetPosition(), setSteps(), driveForward() or driveBackward().

int BrickStepper.getMaxVelocity()
Returns:
  • velocity – Type: int, Unit: 1 1/s, Range: [0 to 216 - 1]

Returns the velocity as set by setMaxVelocity().

int BrickStepper.getCurrentVelocity()
Returns:
  • velocity – Type: int, Unit: 1 1/s, Range: [0 to 216 - 1]

Returns the current velocity of the stepper motor.

void BrickStepper.setSpeedRamping(int acceleration, int deacceleration)
Parameters:
  • acceleration – Type: int, Unit: 1 1/s², Range: [0 to 216 - 1], Default: 1000
  • deacceleration – Type: int, Unit: 1 1/s², Range: [0 to 216 - 1], Default: 1000

Sets the acceleration and deacceleration of the stepper motor. An acceleration of 1000 means, that every second the velocity is increased by 1000 steps/s.

For example: If the current velocity is 0 and you want to accelerate to a velocity of 8000 steps/s in 10 seconds, you should set an acceleration of 800 steps/s².

An acceleration/deacceleration of 0 means instantaneous acceleration/deacceleration (not recommended)

BrickStepper.SpeedRamping BrickStepper.getSpeedRamping()
Return Object:
  • acceleration – Type: int, Unit: 1 1/s², Range: [0 to 216 - 1], Default: 1000
  • deacceleration – Type: int, Unit: 1 1/s², Range: [0 to 216 - 1], Default: 1000

Returns the acceleration and deacceleration as set by setSpeedRamping().

void BrickStepper.fullBrake()

Executes an active full brake.

Warning

This function is for emergency purposes, where an immediate brake is necessary. Depending on the current velocity and the strength of the motor, a full brake can be quite violent.

Call stop() if you just want to stop the motor.

void BrickStepper.setSteps(int steps)
Parameters:
  • steps – Type: int, Range: [-231 to 231 - 1]

Sets the number of steps the stepper motor should run. Positive values will drive the motor forward and negative values backward. The velocity, acceleration and deacceleration as set by setMaxVelocity() and setSpeedRamping() will be used.

int BrickStepper.getSteps()
Returns:
  • steps – Type: int, Range: [-231 to 231 - 1]

Returns the last steps as set by setSteps().

int BrickStepper.getRemainingSteps()
Returns:
  • steps – Type: int, Range: [-231 to 231 - 1]

Returns the remaining steps of the last call of setSteps(). For example, if setSteps() is called with 2000 and getRemainingSteps() is called after the motor has run for 500 steps, it will return 1500.

void BrickStepper.driveForward()

Drives the stepper motor forward until driveBackward() or stop() is called. The velocity, acceleration and deacceleration as set by setMaxVelocity() and setSpeedRamping() will be used.

void BrickStepper.driveBackward()

Drives the stepper motor backward until driveForward() or stop() is triggered. The velocity, acceleration and deacceleration as set by setMaxVelocity() and setSpeedRamping() will be used.

void BrickStepper.stop()

Stops the stepper motor with the deacceleration as set by setSpeedRamping().

void BrickStepper.setMotorCurrent(int current)
Parameters:
  • current – Type: int, Unit: 1 mA, Range: [100 to 2291], Default: 800

Sets the current with which the motor will be driven.

Warning

Do not set this value above the specifications of your stepper motor. Otherwise it may damage your motor.

int BrickStepper.getMotorCurrent()
Returns:
  • current – Type: int, Unit: 1 mA, Range: [100 to 2291], Default: 800

Returns the current as set by setMotorCurrent().

void BrickStepper.enable()

Enables the driver chip. The driver parameters can be configured (maximum velocity, acceleration, etc) before it is enabled.

void BrickStepper.disable()

Disables the driver chip. The configurations are kept (maximum velocity, acceleration, etc) but the motor is not driven until it is enabled again.

Warning

Disabling the driver chip while the motor is still turning can damage the driver chip. The motor should be stopped calling stop() function before disabling the motor power. The stop() function will not wait until the motor is actually stopped. You have to explicitly wait for the appropriate time after calling the stop() function before calling the disable() function.

boolean BrickStepper.isEnabled()
Returns:
  • enabled – Type: boolean, Default: false

Returns true if the driver chip is enabled, false otherwise.

Advanced Functions

void BrickStepper.setCurrentPosition(int position)
Parameters:
  • position – Type: int, Range: [-231 to 231 - 1]

Sets the current steps of the internal step counter. This can be used to set the current position to 0 when some kind of starting position is reached (e.g. when a CNC machine reaches a corner).

int BrickStepper.getCurrentPosition()
Returns:
  • position – Type: int, Range: [-231 to 231 - 1]

Returns the current position of the stepper motor in steps. On startup the position is 0. The steps are counted with all possible driving functions (setTargetPosition(), setSteps(), driveForward() or driveBackward()). It also is possible to reset the steps to 0 or set them to any other desired value with setCurrentPosition().

void BrickStepper.setTargetPosition(int position)
Parameters:
  • position – Type: int, Range: [-231 to 231 - 1]

Sets the target position of the stepper motor in steps. For example, if the current position of the motor is 500 and setTargetPosition() is called with 1000, the stepper motor will drive 500 steps forward. It will use the velocity, acceleration and deacceleration as set by setMaxVelocity() and setSpeedRamping().

A call of setTargetPosition() with the parameter x is equivalent to a call of setSteps() with the parameter (x - getCurrentPosition()).

int BrickStepper.getTargetPosition()
Returns:
  • position – Type: int, Range: [-231 to 231 - 1]

Returns the last target position as set by setTargetPosition().

void BrickStepper.setStepMode(short mode)
Parameters:
  • mode – Type: short, Range: See constants, Default: 8

Sets the step mode of the stepper motor. Possible values are:

  • Full Step = 1
  • Half Step = 2
  • Quarter Step = 4
  • Eighth Step = 8

A higher value will increase the resolution and decrease the torque of the stepper motor.

The following constants are available for this function:

For mode:

  • BrickStepper.STEP_MODE_FULL_STEP = 1
  • BrickStepper.STEP_MODE_HALF_STEP = 2
  • BrickStepper.STEP_MODE_QUARTER_STEP = 4
  • BrickStepper.STEP_MODE_EIGHTH_STEP = 8
short BrickStepper.getStepMode()
Returns:
  • mode – Type: short, Range: See constants, Default: 8

Returns the step mode as set by setStepMode().

The following constants are available for this function:

For mode:

  • BrickStepper.STEP_MODE_FULL_STEP = 1
  • BrickStepper.STEP_MODE_HALF_STEP = 2
  • BrickStepper.STEP_MODE_QUARTER_STEP = 4
  • BrickStepper.STEP_MODE_EIGHTH_STEP = 8
int BrickStepper.getStackInputVoltage()
Returns:
  • voltage – Type: int, Unit: 1 mV, Range: [0 to 216 - 1]

Returns the stack input voltage. The stack input voltage is the voltage that is supplied via the stack, i.e. it is given by a Step-Down or Step-Up Power Supply.

int BrickStepper.getExternalInputVoltage()
Returns:
  • voltage – Type: int, Unit: 1 mV, Range: [0 to 216 - 1]

Returns the external input voltage. The external input voltage is given via the black power input connector on the Stepper Brick.

If there is an external input voltage and a stack input voltage, the motor will be driven by the external input voltage. If there is only a stack voltage present, the motor will be driven by this voltage.

Warning

This means, if you have a high stack voltage and a low external voltage, the motor will be driven with the low external voltage. If you then remove the external connection, it will immediately be driven by the high stack voltage

int BrickStepper.getCurrentConsumption()
Returns:
  • current – Type: int, Unit: 1 mA, Range: [0 to 216 - 1]

Returns the current consumption of the motor.

void BrickStepper.setDecay(int decay)
Parameters:
  • decay – Type: int, Range: [0 to 216 - 1], Default: 10000

Sets the decay mode of the stepper motor. A value of 0 sets the fast decay mode, a value of 65535 sets the slow decay mode and a value in between sets the mixed decay mode.

Changing the decay mode is only possible if synchronous rectification is enabled (see setSyncRect()).

For a good explanation of the different decay modes see this blog post by Avayan.

A good decay mode is unfortunately different for every motor. The best way to work out a good decay mode for your stepper motor, if you can't measure the current with an oscilloscope, is to listen to the sound of the motor. If the value is too low, you often hear a high pitched sound and if it is too high you can often hear a humming sound.

Generally, fast decay mode (small value) will be noisier but also allow higher motor speeds.

Note

There is unfortunately no formula to calculate a perfect decay mode for a given stepper motor. If you have problems with loud noises or the maximum motor speed is too slow, you should try to tinker with the decay value

int BrickStepper.getDecay()
Returns:
  • decay – Type: int, Range: [0 to 216 - 1], Default: 10000

Returns the decay mode as set by setDecay().

void BrickStepper.setSyncRect(boolean syncRect)
Parameters:
  • syncRect – Type: boolean, Default: false

Turns synchronous rectification on or off (true or false).

With synchronous rectification on, the decay can be changed (see setDecay()). Without synchronous rectification fast decay is used.

For an explanation of synchronous rectification see here.

Warning

If you want to use high speeds (> 10000 steps/s) for a large stepper motor with a large inductivity we strongly suggest that you disable synchronous rectification. Otherwise the Brick may not be able to cope with the load and overheat.

boolean BrickStepper.isSyncRect()
Returns:
  • syncRect – Type: boolean, Default: false

Returns true if synchronous rectification is enabled, false otherwise.

void BrickStepper.setTimeBase(long timeBase)
Parameters:
  • timeBase – Type: long, Unit: 1 s, Range: [0 to 232 - 1], Default: 1

Sets the time base of the velocity and the acceleration of the stepper brick.

For example, if you want to make one step every 1.5 seconds, you can set the time base to 15 and the velocity to 10. Now the velocity is 10steps/15s = 1steps/1.5s.

long BrickStepper.getTimeBase()
Returns:
  • timeBase – Type: long, Unit: 1 s, Range: [0 to 232 - 1], Default: 1

Returns the time base as set by setTimeBase().

BrickStepper.AllData BrickStepper.getAllData()
Return Object:
  • currentVelocity – Type: int, Unit: 1 1/s, Range: [0 to 216 - 1]
  • currentPosition – Type: int, Range: [-231 to 231 - 1]
  • remainingSteps – Type: int, Range: [-231 to 231 - 1]
  • stackVoltage – Type: int, Unit: 1 mV, Range: [0 to 216 - 1]
  • externalVoltage – Type: int, Unit: 1 mV, Range: [0 to 216 - 1]
  • currentConsumption – Type: int, Unit: 1 mA, Range: [0 to 216 - 1]

Returns the following parameters: The current velocity, the current position, the remaining steps, the stack voltage, the external voltage and the current consumption of the stepper motor.

There is also a callback for this function, see AllDataCallback callback.

void BrickStepper.setSPITFPBaudrateConfig(boolean enableDynamicBaudrate, long minimumDynamicBaudrate)
Parameters:
  • enableDynamicBaudrate – Type: boolean, Default: true
  • minimumDynamicBaudrate – Type: long, Unit: 1 Bd, Range: [400000 to 2000000], Default: 400000

The SPITF protocol can be used with a dynamic baudrate. If the dynamic baudrate is enabled, the Brick will try to adapt the baudrate for the communication between Bricks and Bricklets according to the amount of data that is transferred.

The baudrate will be increased exponentially if lots of data is sent/received and decreased linearly if little data is sent/received.

This lowers the baudrate in applications where little data is transferred (e.g. a weather station) and increases the robustness. If there is lots of data to transfer (e.g. Thermal Imaging Bricklet) it automatically increases the baudrate as needed.

In cases where some data has to transferred as fast as possible every few seconds (e.g. RS485 Bricklet with a high baudrate but small payload) you may want to turn the dynamic baudrate off to get the highest possible performance.

The maximum value of the baudrate can be set per port with the function setSPITFPBaudrate(). If the dynamic baudrate is disabled, the baudrate as set by setSPITFPBaudrate() will be used statically.

New in version 2.3.6 (Firmware).

BrickStepper.SPITFPBaudrateConfig BrickStepper.getSPITFPBaudrateConfig()
Return Object:
  • enableDynamicBaudrate – Type: boolean, Default: true
  • minimumDynamicBaudrate – Type: long, Unit: 1 Bd, Range: [400000 to 2000000], Default: 400000

Returns the baudrate config, see setSPITFPBaudrateConfig().

New in version 2.3.6 (Firmware).

long BrickStepper.getSendTimeoutCount(short communicationMethod)
Parameters:
  • communicationMethod – Type: short, Range: See constants
Returns:
  • timeoutCount – Type: long, Range: [0 to 232 - 1]

Returns the timeout count for the different communication methods.

The methods 0-2 are available for all Bricks, 3-7 only for Master Bricks.

This function is mostly used for debugging during development, in normal operation the counters should nearly always stay at 0.

The following constants are available for this function:

For communicationMethod:

  • BrickStepper.COMMUNICATION_METHOD_NONE = 0
  • BrickStepper.COMMUNICATION_METHOD_USB = 1
  • BrickStepper.COMMUNICATION_METHOD_SPI_STACK = 2
  • BrickStepper.COMMUNICATION_METHOD_CHIBI = 3
  • BrickStepper.COMMUNICATION_METHOD_RS485 = 4
  • BrickStepper.COMMUNICATION_METHOD_WIFI = 5
  • BrickStepper.COMMUNICATION_METHOD_ETHERNET = 6
  • BrickStepper.COMMUNICATION_METHOD_WIFI_V2 = 7

New in version 2.3.4 (Firmware).

void BrickStepper.setSPITFPBaudrate(char brickletPort, long baudrate)
Parameters:
  • brickletPort – Type: char, Range: ['a' to 'b']
  • baudrate – Type: long, Unit: 1 Bd, Range: [400000 to 2000000], Default: 1400000

Sets the baudrate for a specific Bricklet port.

If you want to increase the throughput of Bricklets you can increase the baudrate. If you get a high error count because of high interference (see getSPITFPErrorCount()) you can decrease the baudrate.

If the dynamic baudrate feature is enabled, the baudrate set by this function corresponds to the maximum baudrate (see setSPITFPBaudrateConfig()).

Regulatory testing is done with the default baudrate. If CE compatibility or similar is necessary in your applications we recommend to not change the baudrate.

New in version 2.3.3 (Firmware).

long BrickStepper.getSPITFPBaudrate(char brickletPort)
Parameters:
  • brickletPort – Type: char, Range: ['a' to 'b']
Returns:
  • baudrate – Type: long, Unit: 1 Bd, Range: [400000 to 2000000], Default: 1400000

Returns the baudrate for a given Bricklet port, see setSPITFPBaudrate().

New in version 2.3.3 (Firmware).

BrickStepper.SPITFPErrorCount BrickStepper.getSPITFPErrorCount(char brickletPort)
Parameters:
  • brickletPort – Type: char, Range: ['a' to 'b']
Return Object:
  • errorCountACKChecksum – Type: long, Range: [0 to 232 - 1]
  • errorCountMessageChecksum – Type: long, Range: [0 to 232 - 1]
  • errorCountFrame – Type: long, Range: [0 to 232 - 1]
  • errorCountOverflow – Type: long, Range: [0 to 232 - 1]

Returns the error count for the communication between Brick and Bricklet.

The errors are divided into

  • ACK checksum errors,
  • message checksum errors,
  • framing errors and
  • overflow errors.

The errors counts are for errors that occur on the Brick side. All Bricklets have a similar function that returns the errors on the Bricklet side.

New in version 2.3.3 (Firmware).

void BrickStepper.enableStatusLED()

Enables the status LED.

The status LED is the blue LED next to the USB connector. If enabled is is on and it flickers if data is transfered. If disabled it is always off.

The default state is enabled.

New in version 2.3.1 (Firmware).

void BrickStepper.disableStatusLED()

Disables the status LED.

The status LED is the blue LED next to the USB connector. If enabled is is on and it flickers if data is transfered. If disabled it is always off.

The default state is enabled.

New in version 2.3.1 (Firmware).

boolean BrickStepper.isStatusLEDEnabled()
Returns:
  • enabled – Type: boolean, Default: true

Returns true if the status LED is enabled, false otherwise.

New in version 2.3.1 (Firmware).

short BrickStepper.getChipTemperature()
Returns:
  • temperature – Type: short, Unit: 1/10 °C, Range: [-215 to 215 - 1]

Returns the temperature as measured inside the microcontroller. The value returned is not the ambient temperature!

The temperature is only proportional to the real temperature and it has an accuracy of ±15%. Practically it is only useful as an indicator for temperature changes.

void BrickStepper.reset()

Calling this function will reset the Brick. Calling this function on a Brick inside of a stack will reset the whole stack.

After a reset you have to create new device objects, calling functions on the existing ones will result in undefined behavior!

BrickStepper.Identity BrickStepper.getIdentity()
Return Object:
  • uid – Type: String, Length: up to 8
  • connectedUid – Type: String, Length: up to 8
  • position – Type: char, Range: ['0' to '8']
  • hardwareVersion – Type: short[], Length: 3
    • 1: major – Type: short, Range: [0 to 255]
    • 2: minor – Type: short, Range: [0 to 255]
    • 3: revision – Type: short, Range: [0 to 255]
  • firmwareVersion – Type: short[], Length: 3
    • 1: major – Type: short, Range: [0 to 255]
    • 2: minor – Type: short, Range: [0 to 255]
    • 3: revision – Type: short, Range: [0 to 255]
  • deviceIdentifier – Type: int, Range: [0 to 216 - 1]

Returns the UID, the UID where the Brick is connected to, the position, the hardware and firmware version as well as the device identifier.

The position is the position in the stack from '0' (bottom) to '8' (top).

The device identifier numbers can be found here. There is also a constant for the device identifier of this Brick.

Callback Configuration Functions

void BrickStepper.setMinimumVoltage(int voltage)
Parameters:
  • voltage – Type: int, Unit: 1 mV, Range: [0 to 216 - 1], Default: 8000

Sets the minimum voltage, below which the UnderVoltageCallback callback is triggered. The minimum possible value that works with the Stepper Brick is 8V. You can use this function to detect the discharge of a battery that is used to drive the stepper motor. If you have a fixed power supply, you likely do not need this functionality.

int BrickStepper.getMinimumVoltage()
Returns:
  • voltage – Type: int, Unit: 1 mV, Range: [0 to 216 - 1], Default: 8000

Returns the minimum voltage as set by setMinimumVoltage().

void BrickStepper.setAllDataPeriod(long period)
Parameters:
  • period – Type: long, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0

Sets the period with which the AllDataCallback callback is triggered periodically. A value of 0 turns the callback off.

long BrickStepper.getAllDataPeriod()
Returns:
  • period – Type: long, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0

Returns the period as set by setAllDataPeriod().

Callbacks

Callbacks can be registered to receive time critical or recurring data from the device. The registration is done with "set" function of MATLAB. The parameters consist of the IP Connection object, the callback name and the callback function. For example, it looks like this in MATLAB:

function my_callback(e)
    fprintf('Parameter: %s\n', e.param);
end

set(device, 'ExampleCallback', @(h, e) my_callback(e));

Due to a difference in the Octave Java support the "set" function cannot be used in Octave. The registration is done with "add*Callback" functions of the device object. It looks like this in Octave:

function my_callback(e)
    fprintf("Parameter: %s\n", e.param);
end

device.addExampleCallback(@my_callback);

It is possible to add several callbacks and to remove them with the corresponding "remove*Callback" function.

The parameters of the callback are passed to the callback function as fields of the structure e, which is derived from the java.util.EventObject class. The available callback names with corresponding structure fields are described below.

Note

Using callbacks for recurring events is always preferred compared to using getters. It will use less USB bandwidth and the latency will be a lot better, since there is no round trip time.

callback BrickStepper.UnderVoltageCallback
Event Object:
  • voltage – Type: int, Unit: 1 mV, Range: [0 to 216 - 1]

This callback is triggered when the input voltage drops below the value set by setMinimumVoltage(). The parameter is the current voltage.

In MATLAB the set() function can be used to register a callback function to this callback.

In Octave a callback function can be added to this callback using the addUnderVoltageCallback() function. An added callback function can be removed with the removeUnderVoltageCallback() function.

callback BrickStepper.PositionReachedCallback
Event Object:
  • position – Type: int, Range: [-231 to 231 - 1]

This callback is triggered when a position set by setSteps() or setTargetPosition() is reached.

Note

Since we can't get any feedback from the stepper motor, this only works if the acceleration (see setSpeedRamping()) is set smaller or equal to the maximum acceleration of the motor. Otherwise the motor will lag behind the control value and the callback will be triggered too early.

In MATLAB the set() function can be used to register a callback function to this callback.

In Octave a callback function can be added to this callback using the addPositionReachedCallback() function. An added callback function can be removed with the removePositionReachedCallback() function.

callback BrickStepper.AllDataCallback
Event Object:
  • currentVelocity – Type: int, Unit: 1 1/s, Range: [0 to 216 - 1]
  • currentPosition – Type: int, Range: [-231 to 231 - 1]
  • remainingSteps – Type: int, Range: [-231 to 231 - 1]
  • stackVoltage – Type: int, Unit: 1 mV, Range: [0 to 216 - 1]
  • externalVoltage – Type: int, Unit: 1 mV, Range: [0 to 216 - 1]
  • currentConsumption – Type: int, Unit: 1 mA, Range: [0 to 216 - 1]

This callback is triggered periodically with the period that is set by setAllDataPeriod(). The parameters are: the current velocity, the current position, the remaining steps, the stack voltage, the external voltage and the current consumption of the stepper motor.

In MATLAB the set() function can be used to register a callback function to this callback.

In Octave a callback function can be added to this callback using the addAllDataCallback() function. An added callback function can be removed with the removeAllDataCallback() function.

callback BrickStepper.NewStateCallback
Event Object:
  • stateNew – Type: short, Range: See constants
  • statePrevious – Type: short, Range: See constants

This callback is triggered whenever the Stepper Brick enters a new state. It returns the new state as well as the previous state.

The following constants are available for this function:

For stateNew:

  • BrickStepper.STATE_STOP = 1
  • BrickStepper.STATE_ACCELERATION = 2
  • BrickStepper.STATE_RUN = 3
  • BrickStepper.STATE_DEACCELERATION = 4
  • BrickStepper.STATE_DIRECTION_CHANGE_TO_FORWARD = 5
  • BrickStepper.STATE_DIRECTION_CHANGE_TO_BACKWARD = 6

For statePrevious:

  • BrickStepper.STATE_STOP = 1
  • BrickStepper.STATE_ACCELERATION = 2
  • BrickStepper.STATE_RUN = 3
  • BrickStepper.STATE_DEACCELERATION = 4
  • BrickStepper.STATE_DIRECTION_CHANGE_TO_FORWARD = 5
  • BrickStepper.STATE_DIRECTION_CHANGE_TO_BACKWARD = 6

In MATLAB the set() function can be used to register a callback function to this callback.

In Octave a callback function can be added to this callback using the addNewStateCallback() function. An added callback function can be removed with the removeNewStateCallback() function.

Virtual Functions

Virtual functions don't communicate with the device itself, but operate only on the API bindings device object. They can be called without the corresponding IP Connection object being connected.

short[] BrickStepper.getAPIVersion()
Return Object:
  • apiVersion – Type: short[], Length: 3
    • 1: major – Type: short, Range: [0 to 255]
    • 2: minor – Type: short, Range: [0 to 255]
    • 3: revision – Type: short, Range: [0 to 255]

Returns the version of the API definition implemented by this API bindings. This is neither the release version of this API bindings nor does it tell you anything about the represented Brick or Bricklet.

boolean BrickStepper.getResponseExpected(byte functionId)
Parameters:
  • functionId – Type: byte, Range: See constants
Returns:
  • responseExpected – Type: boolean

Returns the response expected flag for the function specified by the function ID parameter. It is true if the function is expected to send a response, false otherwise.

For getter functions this is enabled by default and cannot be disabled, because those functions will always send a response. For callback configuration functions it is enabled by default too, but can be disabled by setResponseExpected(). For setter functions it is disabled by default and can be enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.

The following constants are available for this function:

For functionId:

  • BrickStepper.FUNCTION_SET_MAX_VELOCITY = 1
  • BrickStepper.FUNCTION_SET_SPEED_RAMPING = 4
  • BrickStepper.FUNCTION_FULL_BRAKE = 6
  • BrickStepper.FUNCTION_SET_CURRENT_POSITION = 7
  • BrickStepper.FUNCTION_SET_TARGET_POSITION = 9
  • BrickStepper.FUNCTION_SET_STEPS = 11
  • BrickStepper.FUNCTION_SET_STEP_MODE = 14
  • BrickStepper.FUNCTION_DRIVE_FORWARD = 16
  • BrickStepper.FUNCTION_DRIVE_BACKWARD = 17
  • BrickStepper.FUNCTION_STOP = 18
  • BrickStepper.FUNCTION_SET_MOTOR_CURRENT = 22
  • BrickStepper.FUNCTION_ENABLE = 24
  • BrickStepper.FUNCTION_DISABLE = 25
  • BrickStepper.FUNCTION_SET_DECAY = 27
  • BrickStepper.FUNCTION_SET_MINIMUM_VOLTAGE = 29
  • BrickStepper.FUNCTION_SET_SYNC_RECT = 33
  • BrickStepper.FUNCTION_SET_TIME_BASE = 35
  • BrickStepper.FUNCTION_SET_ALL_DATA_PERIOD = 38
  • BrickStepper.FUNCTION_SET_SPITFP_BAUDRATE_CONFIG = 231
  • BrickStepper.FUNCTION_SET_SPITFP_BAUDRATE = 234
  • BrickStepper.FUNCTION_ENABLE_STATUS_LED = 238
  • BrickStepper.FUNCTION_DISABLE_STATUS_LED = 239
  • BrickStepper.FUNCTION_RESET = 243
  • BrickStepper.FUNCTION_WRITE_BRICKLET_PLUGIN = 246
void BrickStepper.setResponseExpected(byte functionId, boolean responseExpected)
Parameters:
  • functionId – Type: byte, Range: See constants
  • responseExpected – Type: boolean

Changes the response expected flag of the function specified by the function ID parameter. This flag can only be changed for setter (default value: false) and callback configuration functions (default value: true). For getter functions it is always enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.

The following constants are available for this function:

For functionId:

  • BrickStepper.FUNCTION_SET_MAX_VELOCITY = 1
  • BrickStepper.FUNCTION_SET_SPEED_RAMPING = 4
  • BrickStepper.FUNCTION_FULL_BRAKE = 6
  • BrickStepper.FUNCTION_SET_CURRENT_POSITION = 7
  • BrickStepper.FUNCTION_SET_TARGET_POSITION = 9
  • BrickStepper.FUNCTION_SET_STEPS = 11
  • BrickStepper.FUNCTION_SET_STEP_MODE = 14
  • BrickStepper.FUNCTION_DRIVE_FORWARD = 16
  • BrickStepper.FUNCTION_DRIVE_BACKWARD = 17
  • BrickStepper.FUNCTION_STOP = 18
  • BrickStepper.FUNCTION_SET_MOTOR_CURRENT = 22
  • BrickStepper.FUNCTION_ENABLE = 24
  • BrickStepper.FUNCTION_DISABLE = 25
  • BrickStepper.FUNCTION_SET_DECAY = 27
  • BrickStepper.FUNCTION_SET_MINIMUM_VOLTAGE = 29
  • BrickStepper.FUNCTION_SET_SYNC_RECT = 33
  • BrickStepper.FUNCTION_SET_TIME_BASE = 35
  • BrickStepper.FUNCTION_SET_ALL_DATA_PERIOD = 38
  • BrickStepper.FUNCTION_SET_SPITFP_BAUDRATE_CONFIG = 231
  • BrickStepper.FUNCTION_SET_SPITFP_BAUDRATE = 234
  • BrickStepper.FUNCTION_ENABLE_STATUS_LED = 238
  • BrickStepper.FUNCTION_DISABLE_STATUS_LED = 239
  • BrickStepper.FUNCTION_RESET = 243
  • BrickStepper.FUNCTION_WRITE_BRICKLET_PLUGIN = 246
void BrickStepper.setResponseExpectedAll(boolean responseExpected)
Parameters:
  • responseExpected – Type: boolean

Changes the response expected flag for all setter and callback configuration functions of this device at once.

Internal Functions

Internal functions are used for maintenance tasks such as flashing a new firmware of changing the UID of a Bricklet. These task should be performed using Brick Viewer instead of using the internal functions directly.

BrickStepper.Protocol1BrickletName BrickStepper.getProtocol1BrickletName(char port)
Parameters:
  • port – Type: char, Range: ['a' to 'b']
Return Object:
  • protocolVersion – Type: short, Range: [0 to 255]
  • firmwareVersion – Type: short[], Length: 3
    • 1: major – Type: short, Range: [0 to 255]
    • 2: minor – Type: short, Range: [0 to 255]
    • 3: revision – Type: short, Range: [0 to 255]
  • name – Type: String, Length: up to 40

Returns the firmware and protocol version and the name of the Bricklet for a given port.

This functions sole purpose is to allow automatic flashing of v1.x.y Bricklet plugins.

void BrickStepper.writeBrickletPlugin(char port, short offset, short[] chunk)
Parameters:
  • port – Type: char, Range: ['a' to 'b']
  • offset – Type: short, Range: [0 to 255]
  • chunk – Type: short[], Length: 32, Range: [0 to 255]

Writes 32 bytes of firmware to the bricklet attached at the given port. The bytes are written to the position offset * 32.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

short[] BrickStepper.readBrickletPlugin(char port, short offset)
Parameters:
  • port – Type: char, Range: ['a' to 'b']
  • offset – Type: short, Range: [0 to 255]
Returns:
  • chunk – Type: short[], Length: 32, Range: [0 to 255]

Reads 32 bytes of firmware from the bricklet attached at the given port. The bytes are read starting at the position offset * 32.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

Constants

int BrickStepper.DEVICE_IDENTIFIER

This constant is used to identify a Stepper Brick.

The getIdentity() function and the IPConnection.EnumerateCallback callback of the IP Connection have a deviceIdentifier parameter to specify the Brick's or Bricklet's type.

String BrickStepper.DEVICE_DISPLAY_NAME

This constant represents the human readable name of a Stepper Brick.