Rust - CO2 Bricklet 2.0

This is the description of the Rust API bindings for the CO2 Bricklet 2.0. General information and technical specifications for the CO2 Bricklet 2.0 are summarized in its hardware description.

An installation guide for the Rust API bindings is part of their general description. Additional documentation can be found on docs.rs.

Examples

The example code below is Public Domain (CC0 1.0).

Simple

Download (example_simple.rs)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
use std::{error::Error, io};

use tinkerforge::{co2_v2_bricklet::*, ip_connection::IpConnection};

const HOST: &str = "localhost";
const PORT: u16 = 4223;
const UID: &str = "XYZ"; // Change XYZ to the UID of your CO2 Bricklet 2.0.

fn main() -> Result<(), Box<dyn Error>> {
    let ipcon = IpConnection::new(); // Create IP connection.
    let co2 = Co2V2Bricklet::new(UID, &ipcon); // Create device object.

    ipcon.connect((HOST, PORT)).recv()??; // Connect to brickd.
                                          // Don't use device before ipcon is connected.

    // Get current all values.
    let all_values = co2.get_all_values().recv()?;

    println!("CO2 Concentration: {} ppm", all_values.co2_concentration);
    println!("Temperature: {} °C", all_values.temperature as f32 / 100.0);
    println!("Humidity: {} %RH", all_values.humidity as f32 / 100.0);

    println!("Press enter to exit.");
    let mut _input = String::new();
    io::stdin().read_line(&mut _input)?;
    ipcon.disconnect();
    Ok(())
}

Callback

Download (example_callback.rs)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
use std::{error::Error, io, thread};
use tinkerforge::{co2_v2_bricklet::*, ip_connection::IpConnection};

const HOST: &str = "localhost";
const PORT: u16 = 4223;
const UID: &str = "XYZ"; // Change XYZ to the UID of your CO2 Bricklet 2.0.

fn main() -> Result<(), Box<dyn Error>> {
    let ipcon = IpConnection::new(); // Create IP connection.
    let co2 = Co2V2Bricklet::new(UID, &ipcon); // Create device object.

    ipcon.connect((HOST, PORT)).recv()??; // Connect to brickd.
                                          // Don't use device before ipcon is connected.

    let all_values_receiver = co2.get_all_values_callback_receiver();

    // Spawn thread to handle received callback messages.
    // This thread ends when the `co2` object
    // is dropped, so there is no need for manual cleanup.
    thread::spawn(move || {
        for all_values in all_values_receiver {
            println!("CO2 Concentration: {} ppm", all_values.co2_concentration);
            println!("Temperature: {} °C", all_values.temperature as f32 / 100.0);
            println!("Humidity: {} %RH", all_values.humidity as f32 / 100.0);
            println!();
        }
    });

    // Set period for all values callback to 1s (1000ms).
    co2.set_all_values_callback_configuration(1000, false);

    println!("Press enter to exit.");
    let mut _input = String::new();
    io::stdin().read_line(&mut _input)?;
    ipcon.disconnect();
    Ok(())
}

API

To allow non-blocking usage, nearly every function of the Rust bindings returns a wrapper around a mpsc::Receiver. To block until the function has finished and get your result, call one of the receiver's recv variants. Those return either the result sent by the device, or any error occurred.

Functions returning a result directly will block until the device has finished processing the request.

All functions listed below are thread-safe, those which return a receiver are lock-free.

Basic Functions

pub fn Co2V2Bricklet::new(uid: &str, ip_connection: &IpConnection) → Co2V2Bricklet
Parameters:
  • uid – Type: &str
  • ip_connection – Type: &IPConnection
Returns:
  • co2_v2 – Type: Co2V2Bricklet

Creates a new Co2V2Bricklet object with the unique device ID uid and adds it to the IPConnection ip_connection:

let co2_v2 = Co2V2Bricklet::new("YOUR_DEVICE_UID", &ip_connection);

This device object can be used after the IP connection has been connected.

pub fn Co2V2Bricklet::get_all_values(&self) → ConvertingReceiver<AllValues>
Return Object:
  • co2_concentration – Type: u16, Unit: 1 ppm, Range: [0 to 40000]
  • temperature – Type: i16, Unit: 1/100 °C, Range: [-4000 to 12000]
  • humidity – Type: u16, Unit: 1/100 %, Range: [0 to 10000]

Returns all values measured by the CO2 Bricklet 2.0.

If you want to get the values periodically, it is recommended to use the Co2V2Bricklet::get_all_values_callback_receiver callback. You can set the callback configuration with Co2V2Bricklet::set_all_values_callback_configuration.

Note

The sensor is able to messure up to 120 °C. However it is only specified up to 70 °C. Exposing the Bricklet to higher temperatures might result in permanent damage.

pub fn Co2V2Bricklet::set_air_pressure(&self, air_pressure: u16) → ConvertingReceiver<()>
Parameters:
  • air_pressure – Type: u16, Unit: 1 hPa, Range: [0, 700 to 1200], Default: 0

The CO2 concentration depends (among other things) on the ambient air pressure.

To increase the accuracy of the CO2 Bricklet 2.0 you can set the current air pressure. You use the Barometer Bricklet 2.0 or the Air Quality Bricklet to get the current air pressure.

By default air pressure compensation is disabled. Once you set a value it will be used for compensation. You can turn the compensation off again by setting the value to 0.

It is sufficient to update the value every few minutes.

pub fn Co2V2Bricklet::get_air_pressure(&self) → ConvertingReceiver<u16>
Returns:
  • air_pressure – Type: u16, Unit: 1 hPa, Range: [0, 700 to 1200], Default: 0

Returns the ambient air pressure as set by Co2V2Bricklet::set_air_pressure.

pub fn Co2V2Bricklet::set_temperature_offset(&self, offset: u16) → ConvertingReceiver<()>
Parameters:
  • offset – Type: u16, Unit: 1/100 °C, Range: [0 to 216 - 1]

Sets a temperature offset. A offset of 10 will decrease the measured temperature by 0.1 °C.

If you install this Bricklet into an enclosure and you want to measure the ambient temperature, you may have to decrease the measured temperature by some value to compensate for the error because of the heating inside of the enclosure.

We recommend that you leave the parts in the enclosure running for at least 24 hours such that a temperature equilibrium can be reached. After that you can measure the temperature directly outside of enclosure and set the difference as offset.

This temperature offset is used to calculate the relative humidity and CO2 concentration. In case the Bricklet is installed in an enclosure, we recommend to measure and set the temperature offset to improve the accuracy of the measurements.

It is sufficient to set the temperature offset once. The offset is saved in non-volatile memory and is applied again after a power loss.

pub fn Co2V2Bricklet::get_temperature_offset(&self) → ConvertingReceiver<u16>
Returns:
  • offset – Type: u16, Unit: 1/100 °C, Range: [0 to 216 - 1]

Returns the temperature offset as set by Co2V2Bricklet::set_temperature_offset.

pub fn Co2V2Bricklet::get_co2_concentration(&self) → ConvertingReceiver<u16>
Returns:
  • co2_concentration – Type: u16, Unit: 1 ppm, Range: [0 to 40000]

Returns CO2 concentration.

If you want to get the value periodically, it is recommended to use the Co2V2Bricklet::get_co2_concentration_callback_receiver callback. You can set the callback configuration with Co2V2Bricklet::set_co2_concentration_callback_configuration.

pub fn Co2V2Bricklet::get_temperature(&self) → ConvertingReceiver<i16>
Returns:
  • temperature – Type: i16, Unit: 1/100 °C, Range: [-4000 to 12000]

Returns temperature.

Note

The sensor is able to messure up to 120 °C. However it is only specified up to 70 °C. Exposing the Bricklet to higher temperatures might result in permanent damage.

If you want to get the value periodically, it is recommended to use the Co2V2Bricklet::get_temperature_callback_receiver callback. You can set the callback configuration with Co2V2Bricklet::set_temperature_callback_configuration.

pub fn Co2V2Bricklet::get_humidity(&self) → ConvertingReceiver<u16>
Returns:
  • humidity – Type: u16, Unit: 1/100 %, Range: [0 to 10000]

Returns relative humidity.

If you want to get the value periodically, it is recommended to use the Co2V2Bricklet::get_humidity_callback_receiver callback. You can set the callback configuration with Co2V2Bricklet::set_humidity_callback_configuration.

Advanced Functions

pub fn Co2V2Bricklet::get_spitfp_error_count(&self) → ConvertingReceiver<SpitfpErrorCount>
Return Object:
  • error_count_ack_checksum – Type: u32, Range: [0 to 232 - 1]
  • error_count_message_checksum – Type: u32, Range: [0 to 232 - 1]
  • error_count_frame – Type: u32, Range: [0 to 232 - 1]
  • error_count_overflow – Type: u32, Range: [0 to 232 - 1]

Returns the error count for the communication between Brick and Bricklet.

The errors are divided into

  • ACK checksum errors,
  • message checksum errors,
  • framing errors and
  • overflow errors.

The errors counts are for errors that occur on the Bricklet side. All Bricks have a similar function that returns the errors on the Brick side.

pub fn Co2V2Bricklet::set_status_led_config(&self, config: u8) → ConvertingReceiver<()>
Parameters:
  • config – Type: u8, Range: See constants, Default: 3

Sets the status LED configuration. By default the LED shows communication traffic between Brick and Bricklet, it flickers once for every 10 received data packets.

You can also turn the LED permanently on/off or show a heartbeat.

If the Bricklet is in bootloader mode, the LED is will show heartbeat by default.

The following constants are available for this function:

For config:

  • CO2_V2_BRICKLET_STATUS_LED_CONFIG_OFF = 0
  • CO2_V2_BRICKLET_STATUS_LED_CONFIG_ON = 1
  • CO2_V2_BRICKLET_STATUS_LED_CONFIG_SHOW_HEARTBEAT = 2
  • CO2_V2_BRICKLET_STATUS_LED_CONFIG_SHOW_STATUS = 3
pub fn Co2V2Bricklet::get_status_led_config(&self) → ConvertingReceiver<u8>
Returns:
  • config – Type: u8, Range: See constants, Default: 3

Returns the configuration as set by Co2V2Bricklet::set_status_led_config

The following constants are available for this function:

For config:

  • CO2_V2_BRICKLET_STATUS_LED_CONFIG_OFF = 0
  • CO2_V2_BRICKLET_STATUS_LED_CONFIG_ON = 1
  • CO2_V2_BRICKLET_STATUS_LED_CONFIG_SHOW_HEARTBEAT = 2
  • CO2_V2_BRICKLET_STATUS_LED_CONFIG_SHOW_STATUS = 3
pub fn Co2V2Bricklet::get_chip_temperature(&self) → ConvertingReceiver<i16>
Returns:
  • temperature – Type: i16, Unit: 1 °C, Range: [-215 to 215 - 1]

Returns the temperature as measured inside the microcontroller. The value returned is not the ambient temperature!

The temperature is only proportional to the real temperature and it has bad accuracy. Practically it is only useful as an indicator for temperature changes.

pub fn Co2V2Bricklet::reset(&self) → ConvertingReceiver<()>

Calling this function will reset the Bricklet. All configurations will be lost.

After a reset you have to create new device objects, calling functions on the existing ones will result in undefined behavior!

pub fn Co2V2Bricklet::get_identity(&self) → ConvertingReceiver<Identity>
Return Object:
  • uid – Type: String, Length: up to 8
  • connected_uid – Type: String, Length: up to 8
  • position – Type: char, Range: ['a' to 'h', 'z']
  • hardware_version – Type: [u8; 3]
    • 0: major – Type: u8, Range: [0 to 255]
    • 1: minor – Type: u8, Range: [0 to 255]
    • 2: revision – Type: u8, Range: [0 to 255]
  • firmware_version – Type: [u8; 3]
    • 0: major – Type: u8, Range: [0 to 255]
    • 1: minor – Type: u8, Range: [0 to 255]
    • 2: revision – Type: u8, Range: [0 to 255]
  • device_identifier – Type: u16, Range: [0 to 216 - 1]

Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.

The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an Isolator Bricklet is always at position 'z'.

The device identifier numbers can be found here. There is also a constant for the device identifier of this Bricklet.

Callback Configuration Functions

pub fn Co2V2Bricklet::set_all_values_callback_configuration(&self, period: u32, value_has_to_change: bool) → ConvertingReceiver<()>
Parameters:
  • period – Type: u32, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • value_has_to_change – Type: bool, Default: false

The period is the period with which the Co2V2Bricklet::get_all_values_callback_receiver callback is triggered periodically. A value of 0 turns the callback off.

If the value has to change-parameter is set to true, the callback is only triggered after at least one of the values has changed. If the values didn't change within the period, the callback is triggered immediately on change.

If it is set to false, the callback is continuously triggered with the period, independent of the value.

pub fn Co2V2Bricklet::get_all_values_callback_configuration(&self) → ConvertingReceiver<AllValuesCallbackConfiguration>
Return Object:
  • period – Type: u32, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • value_has_to_change – Type: bool, Default: false

Returns the callback configuration as set by Co2V2Bricklet::set_all_values_callback_configuration.

pub fn Co2V2Bricklet::set_co2_concentration_callback_configuration(&self, period: u32, value_has_to_change: bool, option: char, min: u16, max: u16) → ConvertingReceiver<()>
Parameters:
  • period – Type: u32, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • value_has_to_change – Type: bool, Default: false
  • option – Type: char, Range: See constants, Default: 'x'
  • min – Type: u16, Unit: 1 ppm, Range: [0 to 216 - 1], Default: 0
  • max – Type: u16, Unit: 1 ppm, Range: [0 to 216 - 1], Default: 0

The period is the period with which the Co2V2Bricklet::get_co2_concentration_callback_receiver callback is triggered periodically. A value of 0 turns the callback off.

If the value has to change-parameter is set to true, the callback is only triggered after the value has changed. If the value didn't change within the period, the callback is triggered immediately on change.

If it is set to false, the callback is continuously triggered with the period, independent of the value.

It is furthermore possible to constrain the callback with thresholds.

The option-parameter together with min/max sets a threshold for the Co2V2Bricklet::get_co2_concentration_callback_receiver callback.

The following options are possible:

Option Description
'x' Threshold is turned off
'o' Threshold is triggered when the value is outside the min and max values
'i' Threshold is triggered when the value is inside or equal to the min and max values
'<' Threshold is triggered when the value is smaller than the min value (max is ignored)
'>' Threshold is triggered when the value is greater than the min value (max is ignored)

If the option is set to 'x' (threshold turned off) the callback is triggered with the fixed period.

The following constants are available for this function:

For option:

  • CO2_V2_BRICKLET_THRESHOLD_OPTION_OFF = 'x'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_OUTSIDE = 'o'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_INSIDE = 'i'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_SMALLER = '<'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_GREATER = '>'
pub fn Co2V2Bricklet::get_co2_concentration_callback_configuration(&self) → ConvertingReceiver<Co2ConcentrationCallbackConfiguration>
Return Object:
  • period – Type: u32, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • value_has_to_change – Type: bool, Default: false
  • option – Type: char, Range: See constants, Default: 'x'
  • min – Type: u16, Unit: 1 ppm, Range: [0 to 216 - 1], Default: 0
  • max – Type: u16, Unit: 1 ppm, Range: [0 to 216 - 1], Default: 0

Returns the callback configuration as set by Co2V2Bricklet::set_co2_concentration_callback_configuration.

The following constants are available for this function:

For option:

  • CO2_V2_BRICKLET_THRESHOLD_OPTION_OFF = 'x'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_OUTSIDE = 'o'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_INSIDE = 'i'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_SMALLER = '<'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_GREATER = '>'
pub fn Co2V2Bricklet::set_temperature_callback_configuration(&self, period: u32, value_has_to_change: bool, option: char, min: i16, max: i16) → ConvertingReceiver<()>
Parameters:
  • period – Type: u32, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • value_has_to_change – Type: bool, Default: false
  • option – Type: char, Range: See constants, Default: 'x'
  • min – Type: i16, Unit: 1/100 °C, Range: [-215 to 215 - 1], Default: 0
  • max – Type: i16, Unit: 1/100 °C, Range: [-215 to 215 - 1], Default: 0

The period is the period with which the Co2V2Bricklet::get_temperature_callback_receiver callback is triggered periodically. A value of 0 turns the callback off.

If the value has to change-parameter is set to true, the callback is only triggered after the value has changed. If the value didn't change within the period, the callback is triggered immediately on change.

If it is set to false, the callback is continuously triggered with the period, independent of the value.

It is furthermore possible to constrain the callback with thresholds.

The option-parameter together with min/max sets a threshold for the Co2V2Bricklet::get_temperature_callback_receiver callback.

The following options are possible:

Option Description
'x' Threshold is turned off
'o' Threshold is triggered when the value is outside the min and max values
'i' Threshold is triggered when the value is inside or equal to the min and max values
'<' Threshold is triggered when the value is smaller than the min value (max is ignored)
'>' Threshold is triggered when the value is greater than the min value (max is ignored)

If the option is set to 'x' (threshold turned off) the callback is triggered with the fixed period.

The following constants are available for this function:

For option:

  • CO2_V2_BRICKLET_THRESHOLD_OPTION_OFF = 'x'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_OUTSIDE = 'o'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_INSIDE = 'i'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_SMALLER = '<'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_GREATER = '>'
pub fn Co2V2Bricklet::get_temperature_callback_configuration(&self) → ConvertingReceiver<TemperatureCallbackConfiguration>
Return Object:
  • period – Type: u32, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • value_has_to_change – Type: bool, Default: false
  • option – Type: char, Range: See constants, Default: 'x'
  • min – Type: i16, Unit: 1/100 °C, Range: [-215 to 215 - 1], Default: 0
  • max – Type: i16, Unit: 1/100 °C, Range: [-215 to 215 - 1], Default: 0

Returns the callback configuration as set by Co2V2Bricklet::set_temperature_callback_configuration.

The following constants are available for this function:

For option:

  • CO2_V2_BRICKLET_THRESHOLD_OPTION_OFF = 'x'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_OUTSIDE = 'o'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_INSIDE = 'i'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_SMALLER = '<'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_GREATER = '>'
pub fn Co2V2Bricklet::set_humidity_callback_configuration(&self, period: u32, value_has_to_change: bool, option: char, min: u16, max: u16) → ConvertingReceiver<()>
Parameters:
  • period – Type: u32, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • value_has_to_change – Type: bool, Default: false
  • option – Type: char, Range: See constants, Default: 'x'
  • min – Type: u16, Unit: 1/100 %, Range: [0 to 216 - 1], Default: 0
  • max – Type: u16, Unit: 1/100 %, Range: [0 to 216 - 1], Default: 0

The period is the period with which the Co2V2Bricklet::get_humidity_callback_receiver callback is triggered periodically. A value of 0 turns the callback off.

If the value has to change-parameter is set to true, the callback is only triggered after the value has changed. If the value didn't change within the period, the callback is triggered immediately on change.

If it is set to false, the callback is continuously triggered with the period, independent of the value.

It is furthermore possible to constrain the callback with thresholds.

The option-parameter together with min/max sets a threshold for the Co2V2Bricklet::get_humidity_callback_receiver callback.

The following options are possible:

Option Description
'x' Threshold is turned off
'o' Threshold is triggered when the value is outside the min and max values
'i' Threshold is triggered when the value is inside or equal to the min and max values
'<' Threshold is triggered when the value is smaller than the min value (max is ignored)
'>' Threshold is triggered when the value is greater than the min value (max is ignored)

If the option is set to 'x' (threshold turned off) the callback is triggered with the fixed period.

The following constants are available for this function:

For option:

  • CO2_V2_BRICKLET_THRESHOLD_OPTION_OFF = 'x'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_OUTSIDE = 'o'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_INSIDE = 'i'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_SMALLER = '<'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_GREATER = '>'
pub fn Co2V2Bricklet::get_humidity_callback_configuration(&self) → ConvertingReceiver<HumidityCallbackConfiguration>
Return Object:
  • period – Type: u32, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • value_has_to_change – Type: bool, Default: false
  • option – Type: char, Range: See constants, Default: 'x'
  • min – Type: u16, Unit: 1/100 %, Range: [0 to 216 - 1], Default: 0
  • max – Type: u16, Unit: 1/100 %, Range: [0 to 216 - 1], Default: 0

Returns the callback configuration as set by Co2V2Bricklet::set_humidity_callback_configuration.

The following constants are available for this function:

For option:

  • CO2_V2_BRICKLET_THRESHOLD_OPTION_OFF = 'x'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_OUTSIDE = 'o'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_INSIDE = 'i'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_SMALLER = '<'
  • CO2_V2_BRICKLET_THRESHOLD_OPTION_GREATER = '>'

Callbacks

Callbacks can be registered to receive time critical or recurring data from the device. The registration is done with the corresponding get_*_callback_receiver function, which returns a receiver for callback events.

Note

Using callbacks for recurring events is always preferred compared to using getters. It will use less USB bandwidth and the latency will be a lot better, since there is no round trip time.

pub fn Co2V2Bricklet::get_all_values_callback_receiver(&self) → ConvertingCallbackReceiver<AllValuesEvent>
Event Object:
  • co2_concentration – Type: u16, Unit: 1 ppm, Range: [0 to 40000]
  • temperature – Type: i16, Unit: 1/100 °C, Range: [-4000 to 12000]
  • humidity – Type: u16, Unit: 1/100 %, Range: [0 to 10000]

Receivers created with this function receive All Values events.

This callback is triggered periodically according to the configuration set by Co2V2Bricklet::set_all_values_callback_configuration.

The members of the received struct are the same as Co2V2Bricklet::get_all_values.

Note

The sensor is able to messure up to 120 °C. However it is only specified up to 70 °C. Exposing the Bricklet to higher temperatures might result in permanent damage.

pub fn Co2V2Bricklet::get_co2_concentration_callback_receiver(&self) → ConvertingCallbackReceiver<u16>
Event:
  • co2_concentration – Type: u16, Unit: 1 ppm, Range: [0 to 40000]

Receivers created with this function receive CO2 Concentration events.

This callback is triggered periodically according to the configuration set by Co2V2Bricklet::set_co2_concentration_callback_configuration.

The received variable is the same as Co2V2Bricklet::get_co2_concentration.

pub fn Co2V2Bricklet::get_temperature_callback_receiver(&self) → ConvertingCallbackReceiver<i16>
Event:
  • temperature – Type: i16, Unit: 1/100 °C, Range: [-4000 to 12000]

Receivers created with this function receive Temperature events.

This callback is triggered periodically according to the configuration set by Co2V2Bricklet::set_temperature_callback_configuration.

The received variable is the same as Co2V2Bricklet::get_temperature.

pub fn Co2V2Bricklet::get_humidity_callback_receiver(&self) → ConvertingCallbackReceiver<u16>
Event:
  • humidity – Type: u16, Unit: 1/100 %, Range: [0 to 10000]

Receivers created with this function receive Humidity events.

This callback is triggered periodically according to the configuration set by Co2V2Bricklet::set_humidity_callback_configuration.

The received variable is the same as Co2V2Bricklet::get_humidity.

Virtual Functions

Virtual functions don't communicate with the device itself, but operate only on the API bindings device object. They can be called without the corresponding IP Connection object being connected.

pub fn Co2V2Bricklet::get_api_version(&self) → [u8; 3]
Return Object:
  • api_version – Type: [u8; 3]
    • 0: major – Type: u8, Range: [0 to 255]
    • 1: minor – Type: u8, Range: [0 to 255]
    • 2: revision – Type: u8, Range: [0 to 255]

Returns the version of the API definition implemented by this API bindings. This is neither the release version of this API bindings nor does it tell you anything about the represented Brick or Bricklet.

pub fn Co2V2Bricklet::get_response_expected(&mut self, function_id: u8) → bool
Parameters:
  • function_id – Type: u8, Range: See constants
Returns:
  • response_expected – Type: bool

Returns the response expected flag for the function specified by the function ID parameter. It is true if the function is expected to send a response, false otherwise.

For getter functions this is enabled by default and cannot be disabled, because those functions will always send a response. For callback configuration functions it is enabled by default too, but can be disabled by Co2V2Bricklet::set_response_expected. For setter functions it is disabled by default and can be enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.

The following constants are available for this function:

For function_id:

  • CO2_V2_BRICKLET_FUNCTION_SET_AIR_PRESSURE = 2
  • CO2_V2_BRICKLET_FUNCTION_SET_TEMPERATURE_OFFSET = 4
  • CO2_V2_BRICKLET_FUNCTION_SET_ALL_VALUES_CALLBACK_CONFIGURATION = 6
  • CO2_V2_BRICKLET_FUNCTION_SET_CO2_CONCENTRATION_CALLBACK_CONFIGURATION = 10
  • CO2_V2_BRICKLET_FUNCTION_SET_TEMPERATURE_CALLBACK_CONFIGURATION = 14
  • CO2_V2_BRICKLET_FUNCTION_SET_HUMIDITY_CALLBACK_CONFIGURATION = 18
  • CO2_V2_BRICKLET_FUNCTION_SET_WRITE_FIRMWARE_POINTER = 237
  • CO2_V2_BRICKLET_FUNCTION_SET_STATUS_LED_CONFIG = 239
  • CO2_V2_BRICKLET_FUNCTION_RESET = 243
  • CO2_V2_BRICKLET_FUNCTION_WRITE_UID = 248
pub fn Co2V2Bricklet::set_response_expected(&mut self, function_id: u8, response_expected: bool) → ()
Parameters:
  • function_id – Type: u8, Range: See constants
  • response_expected – Type: bool

Changes the response expected flag of the function specified by the function ID parameter. This flag can only be changed for setter (default value: false) and callback configuration functions (default value: true). For getter functions it is always enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.

The following constants are available for this function:

For function_id:

  • CO2_V2_BRICKLET_FUNCTION_SET_AIR_PRESSURE = 2
  • CO2_V2_BRICKLET_FUNCTION_SET_TEMPERATURE_OFFSET = 4
  • CO2_V2_BRICKLET_FUNCTION_SET_ALL_VALUES_CALLBACK_CONFIGURATION = 6
  • CO2_V2_BRICKLET_FUNCTION_SET_CO2_CONCENTRATION_CALLBACK_CONFIGURATION = 10
  • CO2_V2_BRICKLET_FUNCTION_SET_TEMPERATURE_CALLBACK_CONFIGURATION = 14
  • CO2_V2_BRICKLET_FUNCTION_SET_HUMIDITY_CALLBACK_CONFIGURATION = 18
  • CO2_V2_BRICKLET_FUNCTION_SET_WRITE_FIRMWARE_POINTER = 237
  • CO2_V2_BRICKLET_FUNCTION_SET_STATUS_LED_CONFIG = 239
  • CO2_V2_BRICKLET_FUNCTION_RESET = 243
  • CO2_V2_BRICKLET_FUNCTION_WRITE_UID = 248
pub fn Co2V2Bricklet::set_response_expected_all(&mut self, response_expected: bool) → ()
Parameters:
  • response_expected – Type: bool

Changes the response expected flag for all setter and callback configuration functions of this device at once.

Internal Functions

Internal functions are used for maintenance tasks such as flashing a new firmware of changing the UID of a Bricklet. These task should be performed using Brick Viewer instead of using the internal functions directly.

pub fn Co2V2Bricklet::set_bootloader_mode(&self, mode: u8) → ConvertingReceiver<u8>
Parameters:
  • mode – Type: u8, Range: See constants
Returns:
  • status – Type: u8, Range: See constants

Sets the bootloader mode and returns the status after the requested mode change was instigated.

You can change from bootloader mode to firmware mode and vice versa. A change from bootloader mode to firmware mode will only take place if the entry function, device identifier and CRC are present and correct.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

The following constants are available for this function:

For mode:

  • CO2_V2_BRICKLET_BOOTLOADER_MODE_BOOTLOADER = 0
  • CO2_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE = 1
  • CO2_V2_BRICKLET_BOOTLOADER_MODE_BOOTLOADER_WAIT_FOR_REBOOT = 2
  • CO2_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_REBOOT = 3
  • CO2_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_ERASE_AND_REBOOT = 4

For status:

  • CO2_V2_BRICKLET_BOOTLOADER_STATUS_OK = 0
  • CO2_V2_BRICKLET_BOOTLOADER_STATUS_INVALID_MODE = 1
  • CO2_V2_BRICKLET_BOOTLOADER_STATUS_NO_CHANGE = 2
  • CO2_V2_BRICKLET_BOOTLOADER_STATUS_ENTRY_FUNCTION_NOT_PRESENT = 3
  • CO2_V2_BRICKLET_BOOTLOADER_STATUS_DEVICE_IDENTIFIER_INCORRECT = 4
  • CO2_V2_BRICKLET_BOOTLOADER_STATUS_CRC_MISMATCH = 5
pub fn Co2V2Bricklet::get_bootloader_mode(&self) → ConvertingReceiver<u8>
Returns:
  • mode – Type: u8, Range: See constants

Returns the current bootloader mode, see Co2V2Bricklet::set_bootloader_mode.

The following constants are available for this function:

For mode:

  • CO2_V2_BRICKLET_BOOTLOADER_MODE_BOOTLOADER = 0
  • CO2_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE = 1
  • CO2_V2_BRICKLET_BOOTLOADER_MODE_BOOTLOADER_WAIT_FOR_REBOOT = 2
  • CO2_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_REBOOT = 3
  • CO2_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_ERASE_AND_REBOOT = 4
pub fn Co2V2Bricklet::set_write_firmware_pointer(&self, pointer: u32) → ConvertingReceiver<()>
Parameters:
  • pointer – Type: u32, Unit: 1 B, Range: [0 to 232 - 1]

Sets the firmware pointer for Co2V2Bricklet::write_firmware. The pointer has to be increased by chunks of size 64. The data is written to flash every 4 chunks (which equals to one page of size 256).

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

pub fn Co2V2Bricklet::write_firmware(&self, data: [u8; 64]) → ConvertingReceiver<u8>
Parameters:
  • data – Type: [u8; 64], Range: [0 to 255]
Returns:
  • status – Type: u8, Range: [0 to 255]

Writes 64 Bytes of firmware at the position as written by Co2V2Bricklet::set_write_firmware_pointer before. The firmware is written to flash every 4 chunks.

You can only write firmware in bootloader mode.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

pub fn Co2V2Bricklet::write_uid(&self, uid: u32) → ConvertingReceiver<()>
Parameters:
  • uid – Type: u32, Range: [0 to 232 - 1]

Writes a new UID into flash. If you want to set a new UID you have to decode the Base58 encoded UID string into an integer first.

We recommend that you use Brick Viewer to change the UID.

pub fn Co2V2Bricklet::read_uid(&self) → ConvertingReceiver<u32>
Returns:
  • uid – Type: u32, Range: [0 to 232 - 1]

Returns the current UID as an integer. Encode as Base58 to get the usual string version.

Constants

pub const Co2V2Bricklet::DEVICE_IDENTIFIER

This constant is used to identify a CO2 Bricklet 2.0.

The Co2V2Bricklet::get_identity function and the IpConnection::get_enumerate_callback_receiver callback of the IP Connection have a device_identifier parameter to specify the Brick's or Bricklet's type.

pub const Co2V2Bricklet::DEVICE_DISPLAY_NAME

This constant represents the human readable name of a CO2 Bricklet 2.0.