C/C++ - Industrial Quad Relay Bricklet

This is the description of the C/C++ API bindings for the Industrial Quad Relay Bricklet. General information and technical specifications for the Industrial Quad Relay Bricklet are summarized in its hardware description.

An installation guide for the C/C++ API bindings is part of their general description.

Examples

The example code below is Public Domain (CC0 1.0).

Simple

Download (example_simple.c)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
#define IPCON_EXPOSE_MILLISLEEP

#include <stdio.h>

#include "ip_connection.h"
#include "bricklet_industrial_quad_relay.h"

#define HOST "localhost"
#define PORT 4223
#define UID "XYZ" // Change XYZ to the UID of your Industrial Quad Relay Bricklet

int main(void) {
    // Create IP connection
    IPConnection ipcon;
    ipcon_create(&ipcon);

    // Create device object
    IndustrialQuadRelay iqr;
    industrial_quad_relay_create(&iqr, UID, &ipcon);

    // Connect to brickd
    if(ipcon_connect(&ipcon, HOST, PORT) < 0) {
        fprintf(stderr, "Could not connect\n");
        return 1;
    }
    // Don't use device before ipcon is connected

    // Turn relays alternating on/off 10 times with 100 ms delay
    int i;
    for(i = 0; i < 10; ++i) {
        millisleep(100);
        industrial_quad_relay_set_value(&iqr, 1 << 0);
        millisleep(100);
        industrial_quad_relay_set_value(&iqr, 1 << 1);
        millisleep(100);
        industrial_quad_relay_set_value(&iqr, 1 << 2);
        millisleep(100);
        industrial_quad_relay_set_value(&iqr, 1 << 3);
    }

    printf("Press key to exit\n");
    getchar();
    industrial_quad_relay_destroy(&iqr);
    ipcon_destroy(&ipcon); // Calls ipcon_disconnect internally
    return 0;
}

API

Most functions of the C/C++ bindings return an error code (e_code). Data returned from the device, when a getter is called, is handled via output parameters. These parameters are labeled with the ret_ prefix.

Possible error codes are:

  • E_OK = 0
  • E_TIMEOUT = -1
  • E_NO_STREAM_SOCKET = -2
  • E_HOSTNAME_INVALID = -3
  • E_NO_CONNECT = -4
  • E_NO_THREAD = -5
  • E_NOT_ADDED = -6 (unused since C/C++ bindings version 2.0.0)
  • E_ALREADY_CONNECTED = -7
  • E_NOT_CONNECTED = -8
  • E_INVALID_PARAMETER = -9
  • E_NOT_SUPPORTED = -10
  • E_UNKNOWN_ERROR_CODE = -11
  • E_STREAM_OUT_OF_SYNC = -12
  • E_INVALID_UID = -13
  • E_NON_ASCII_CHAR_IN_SECRET = -14
  • E_WRONG_DEVICE_TYPE = -15
  • E_DEVICE_REPLACED = -16
  • E_WRONG_RESPONSE_LENGTH = -17

as defined in ip_connection.h.

All functions listed below are thread-safe.

Basic Functions

void industrial_quad_relay_create(IndustrialQuadRelay *industrial_quad_relay, const char *uid, IPConnection *ipcon)
Parameters:
  • industrial_quad_relay – Type: IndustrialQuadRelay *
  • uid – Type: const char *
  • ipcon – Type: IPConnection *

Creates the device object industrial_quad_relay with the unique device ID uid and adds it to the IPConnection ipcon:

IndustrialQuadRelay industrial_quad_relay;
industrial_quad_relay_create(&industrial_quad_relay, "YOUR_DEVICE_UID", &ipcon);

This device object can be used after the IP connection has been connected.

void industrial_quad_relay_destroy(IndustrialQuadRelay *industrial_quad_relay)
Parameters:
  • industrial_quad_relay – Type: IndustrialQuadRelay *

Removes the device object industrial_quad_relay from its IPConnection and destroys it. The device object cannot be used anymore afterwards.

int industrial_quad_relay_set_value(IndustrialQuadRelay *industrial_quad_relay, uint16_t value_mask)
Parameters:
  • industrial_quad_relay – Type: IndustrialQuadRelay *
  • value_mask – Type: uint16_t, Range: [0 to 216 - 1]
Returns:
  • e_code – Type: int

Sets the output value with a bitmask (16bit). A 1 in the bitmask means relay closed and a 0 means relay open.

For example: The value 3 or 0b0011 will close the relay of pins 0-1 and open the other pins.

If no groups are used (see industrial_quad_relay_set_group()), the pins correspond to the markings on the Industrial Quad Relay Bricklet.

If groups are used, the pins correspond to the element in the group. Element 1 in the group will get pins 0-3, element 2 pins 4-7, element 3 pins 8-11 and element 4 pins 12-15.

All running monoflop timers will be aborted if this function is called.

int industrial_quad_relay_get_value(IndustrialQuadRelay *industrial_quad_relay, uint16_t *ret_value_mask)
Parameters:
  • industrial_quad_relay – Type: IndustrialQuadRelay *
Output Parameters:
  • ret_value_mask – Type: uint16_t, Range: [0 to 216 - 1]
Returns:
  • e_code – Type: int

Returns the bitmask as set by industrial_quad_relay_set_value().

Advanced Functions

int industrial_quad_relay_set_monoflop(IndustrialQuadRelay *industrial_quad_relay, uint16_t selection_mask, uint16_t value_mask, uint32_t time)
Parameters:
  • industrial_quad_relay – Type: IndustrialQuadRelay *
  • selection_mask – Type: uint16_t, Range: [0 to 216 - 1]
  • value_mask – Type: uint16_t, Range: [0 to 216 - 1]
  • time – Type: uint32_t, Unit: 1 ms, Range: [0 to 232 - 1]
Returns:
  • e_code – Type: int

Configures a monoflop of the pins specified by the first parameter bitmask.

The second parameter is a bitmask with the desired value of the specified pins. A 1 in the bitmask means relay closed and a 0 means relay open.

The third parameter indicates the time that the pins should hold the value.

If this function is called with the parameters (9, 1, 1500) or (0b1001, 0b0001, 1500): Pin 0 will close and pin 3 will open. In 1.5s pin 0 will open and pin 3 will close again.

A monoflop can be used as a fail-safe mechanism. For example: Lets assume you have a RS485 bus and a Quad Relay Bricklet connected to one of the slave stacks. You can now call this function every second, with a time parameter of two seconds and pin 0 closed. Pin 0 will be closed all the time. If now the RS485 connection is lost, then pin 0 will be opened in at most two seconds.

int industrial_quad_relay_get_monoflop(IndustrialQuadRelay *industrial_quad_relay, uint8_t pin, uint16_t *ret_value, uint32_t *ret_time, uint32_t *ret_time_remaining)
Parameters:
  • industrial_quad_relay – Type: IndustrialQuadRelay *
  • pin – Type: uint8_t, Range: [0 to 15]
Output Parameters:
  • ret_value – Type: uint16_t, Range: [0 to 1]
  • ret_time – Type: uint32_t, Unit: 1 ms, Range: [0 to 232 - 1]
  • ret_time_remaining – Type: uint32_t, Unit: 1 ms, Range: [0 to 232 - 1]
Returns:
  • e_code – Type: int

Returns (for the given pin) the current value and the time as set by industrial_quad_relay_set_monoflop() as well as the remaining time until the value flips.

If the timer is not running currently, the remaining time will be returned as 0.

int industrial_quad_relay_set_group(IndustrialQuadRelay *industrial_quad_relay, char group[4])
Parameters:
  • industrial_quad_relay – Type: IndustrialQuadRelay *
  • group – Type: char[4], Range: ['a' to 'd', 'n']
Returns:
  • e_code – Type: int

Sets a group of Quad Relay Bricklets that should work together. You can find Bricklets that can be grouped together with industrial_quad_relay_get_available_for_group().

The group consists of 4 elements. Element 1 in the group will get pins 0-3, element 2 pins 4-7, element 3 pins 8-11 and element 4 pins 12-15.

Each element can either be one of the ports ('a' to 'd') or 'n' if it should not be used.

For example: If you have two Quad Relay Bricklets connected to port A and port B respectively, you could call with ['a', 'b', 'n', 'n'].

Now the pins on the Quad Relay on port A are assigned to 0-3 and the pins on the Quad Relay on port B are assigned to 4-7. It is now possible to call industrial_quad_relay_set_value() and control two Bricklets at the same time.

int industrial_quad_relay_get_group(IndustrialQuadRelay *industrial_quad_relay, char ret_group[4])
Parameters:
  • industrial_quad_relay – Type: IndustrialQuadRelay *
Output Parameters:
  • ret_group – Type: char[4], Range: ['a' to 'd', 'n']
Returns:
  • e_code – Type: int

Returns the group as set by industrial_quad_relay_set_group()

int industrial_quad_relay_get_available_for_group(IndustrialQuadRelay *industrial_quad_relay, uint8_t *ret_available)
Parameters:
  • industrial_quad_relay – Type: IndustrialQuadRelay *
Output Parameters:
  • ret_available – Type: uint8_t, Range: [0 to 15]
Returns:
  • e_code – Type: int

Returns a bitmask of ports that are available for grouping. For example the value 5 or 0b0101 means: Port A and port C are connected to Bricklets that can be grouped together.

int industrial_quad_relay_set_selected_values(IndustrialQuadRelay *industrial_quad_relay, uint16_t selection_mask, uint16_t value_mask)
Parameters:
  • industrial_quad_relay – Type: IndustrialQuadRelay *
  • selection_mask – Type: uint16_t, Range: [0 to 216 - 1]
  • value_mask – Type: uint16_t, Range: [0 to 216 - 1]
Returns:
  • e_code – Type: int

Sets the output value with a bitmask, according to the selection mask. The bitmask is 16 bit long, true refers to a closed relay and false refers to an open relay.

For example: The values (3, 1) or (0b0011, 0b0001) will close the relay of pin 0, open the relay of pin 1 and leave the others untouched.

If no groups are used (see industrial_quad_relay_set_group()), the pins correspond to the markings on the Industrial Quad Relay Bricklet.

If groups are used, the pins correspond to the element in the group. Element 1 in the group will get pins 0-3, element 2 pins 4-7, element 3 pins 8-11 and element 4 pins 12-15.

Running monoflop timers for the selected relays will be aborted if this function is called.

int industrial_quad_relay_get_identity(IndustrialQuadRelay *industrial_quad_relay, char ret_uid[8], char ret_connected_uid[8], char *ret_position, uint8_t ret_hardware_version[3], uint8_t ret_firmware_version[3], uint16_t *ret_device_identifier)
Parameters:
  • industrial_quad_relay – Type: IndustrialQuadRelay *
Output Parameters:
  • ret_uid – Type: char[8]
  • ret_connected_uid – Type: char[8]
  • ret_position – Type: char, Range: ['a' to 'h', 'z']
  • ret_hardware_version – Type: uint8_t[3]
    • 0: major – Type: uint8_t, Range: [0 to 255]
    • 1: minor – Type: uint8_t, Range: [0 to 255]
    • 2: revision – Type: uint8_t, Range: [0 to 255]
  • ret_firmware_version – Type: uint8_t[3]
    • 0: major – Type: uint8_t, Range: [0 to 255]
    • 1: minor – Type: uint8_t, Range: [0 to 255]
    • 2: revision – Type: uint8_t, Range: [0 to 255]
  • ret_device_identifier – Type: uint16_t, Range: [0 to 216 - 1]
Returns:
  • e_code – Type: int

Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.

The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an Isolator Bricklet is always at position 'z'.

The device identifier numbers can be found here. There is also a constant for the device identifier of this Bricklet.

Callback Configuration Functions

void industrial_quad_relay_register_callback(IndustrialQuadRelay *industrial_quad_relay, int16_t callback_id, void (*function)(void), void *user_data)
Parameters:
  • industrial_quad_relay – Type: IndustrialQuadRelay *
  • callback_id – Type: int16_t
  • function – Type: void (*)(void)
  • user_data – Type: void *

Registers the given function with the given callback_id. The user_data will be passed as the last parameter to the function.

The available callback IDs with corresponding function signatures are listed below.

Callbacks

Callbacks can be registered to receive time critical or recurring data from the device. The registration is done with the industrial_quad_relay_register_callback() function:

void my_callback(int value, void *user_data) {
    printf("Value: %d\n", value);
}

industrial_quad_relay_register_callback(&industrial_quad_relay,
                                        INDUSTRIAL_QUAD_RELAY_CALLBACK_EXAMPLE,
                                        (void (*)(void))my_callback,
                                        NULL);

The available constants with corresponding function signatures are described below.

Note

Using callbacks for recurring events is always preferred compared to using getters. It will use less USB bandwidth and the latency will be a lot better, since there is no round trip time.

INDUSTRIAL_QUAD_RELAY_CALLBACK_MONOFLOP_DONE
void callback(uint16_t selection_mask, uint16_t value_mask, void *user_data)
Callback Parameters:
  • selection_mask – Type: uint16_t, Range: [0 to 216 - 1]
  • value_mask – Type: uint16_t, Range: [0 to 216 - 1]
  • user_data – Type: void *

This callback is triggered whenever a monoflop timer reaches 0. The parameters contain the involved pins and the current value of the pins (the value after the monoflop).

Virtual Functions

Virtual functions don't communicate with the device itself, but operate only on the API bindings device object. They can be called without the corresponding IP Connection object being connected.

int industrial_quad_relay_get_api_version(IndustrialQuadRelay *industrial_quad_relay, uint8_t ret_api_version[3])
Parameters:
  • industrial_quad_relay – Type: IndustrialQuadRelay *
Output Parameters:
  • ret_api_version – Type: uint8_t[3]
    • 0: major – Type: uint8_t, Range: [0 to 255]
    • 1: minor – Type: uint8_t, Range: [0 to 255]
    • 2: revision – Type: uint8_t, Range: [0 to 255]
Returns:
  • e_code – Type: int

Returns the version of the API definition implemented by this API bindings. This is neither the release version of this API bindings nor does it tell you anything about the represented Brick or Bricklet.

int industrial_quad_relay_get_response_expected(IndustrialQuadRelay *industrial_quad_relay, uint8_t function_id, bool *ret_response_expected)
Parameters:
  • industrial_quad_relay – Type: IndustrialQuadRelay *
  • function_id – Type: uint8_t, Range: See constants
Output Parameters:
  • ret_response_expected – Type: bool
Returns:
  • e_code – Type: int

Returns the response expected flag for the function specified by the function ID parameter. It is true if the function is expected to send a response, false otherwise.

For getter functions this is enabled by default and cannot be disabled, because those functions will always send a response. For callback configuration functions it is enabled by default too, but can be disabled by industrial_quad_relay_set_response_expected(). For setter functions it is disabled by default and can be enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.

The following constants are available for this function:

For function_id:

  • INDUSTRIAL_QUAD_RELAY_FUNCTION_SET_VALUE = 1
  • INDUSTRIAL_QUAD_RELAY_FUNCTION_SET_MONOFLOP = 3
  • INDUSTRIAL_QUAD_RELAY_FUNCTION_SET_GROUP = 5
  • INDUSTRIAL_QUAD_RELAY_FUNCTION_SET_SELECTED_VALUES = 9
int industrial_quad_relay_set_response_expected(IndustrialQuadRelay *industrial_quad_relay, uint8_t function_id, bool response_expected)
Parameters:
  • industrial_quad_relay – Type: IndustrialQuadRelay *
  • function_id – Type: uint8_t, Range: See constants
  • response_expected – Type: bool
Returns:
  • e_code – Type: int

Changes the response expected flag of the function specified by the function ID parameter. This flag can only be changed for setter (default value: false) and callback configuration functions (default value: true). For getter functions it is always enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.

The following constants are available for this function:

For function_id:

  • INDUSTRIAL_QUAD_RELAY_FUNCTION_SET_VALUE = 1
  • INDUSTRIAL_QUAD_RELAY_FUNCTION_SET_MONOFLOP = 3
  • INDUSTRIAL_QUAD_RELAY_FUNCTION_SET_GROUP = 5
  • INDUSTRIAL_QUAD_RELAY_FUNCTION_SET_SELECTED_VALUES = 9
int industrial_quad_relay_set_response_expected_all(IndustrialQuadRelay *industrial_quad_relay, bool response_expected)
Parameters:
  • industrial_quad_relay – Type: IndustrialQuadRelay *
  • response_expected – Type: bool
Returns:
  • e_code – Type: int

Changes the response expected flag for all setter and callback configuration functions of this device at once.

Constants

INDUSTRIAL_QUAD_RELAY_DEVICE_IDENTIFIER

This constant is used to identify a Industrial Quad Relay Bricklet.

The industrial_quad_relay_get_identity() function and the IPCON_CALLBACK_ENUMERATE callback of the IP Connection have a device_identifier parameter to specify the Brick's or Bricklet's type.

INDUSTRIAL_QUAD_RELAY_DEVICE_DISPLAY_NAME

This constant represents the human readable name of a Industrial Quad Relay Bricklet.