Go - Moisture Bricklet

This is the description of the Go API bindings for the Moisture Bricklet. General information and technical specifications for the Moisture Bricklet are summarized in its hardware description.

An installation guide for the Go API bindings is part of their general description. Additional documentation can be found on godoc.org.

Examples

The example code below is Public Domain (CC0 1.0).

Simple

Download (example_simple.go)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
package main

import (
    "fmt"
    "github.com/Tinkerforge/go-api-bindings/ipconnection"
    "github.com/Tinkerforge/go-api-bindings/moisture_bricklet"
)

const ADDR string = "localhost:4223"
const UID string = "XYZ" // Change XYZ to the UID of your Moisture Bricklet.

func main() {
    ipcon := ipconnection.New()
    defer ipcon.Close()
    m, _ := moisture_bricklet.New(UID, &ipcon) // Create device object.

    ipcon.Connect(ADDR) // Connect to brickd.
    defer ipcon.Disconnect()
    // Don't use device before ipcon is connected.

    // Get current moisture value.
    moisture, _ := m.GetMoistureValue()
    fmt.Printf("Moisture Value: \n", moisture)

    fmt.Print("Press enter to exit.")
    fmt.Scanln()
}

Callback

Download (example_callback.go)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
package main

import (
    "fmt"
    "github.com/Tinkerforge/go-api-bindings/ipconnection"
    "github.com/Tinkerforge/go-api-bindings/moisture_bricklet"
)

const ADDR string = "localhost:4223"
const UID string = "XYZ" // Change XYZ to the UID of your Moisture Bricklet.

func main() {
    ipcon := ipconnection.New()
    defer ipcon.Close()
    m, _ := moisture_bricklet.New(UID, &ipcon) // Create device object.

    ipcon.Connect(ADDR) // Connect to brickd.
    defer ipcon.Disconnect()
    // Don't use device before ipcon is connected.

    m.RegisterMoistureCallback(func(moisture uint16) {
        fmt.Printf("Moisture Value: %d\n", moisture)
    })

    // Set period for moisture value receiver to 1s (1000ms).
    // Note: The moisture value callback is only called every second
    //       if the moisture value has changed since the last call!
    m.SetMoistureCallbackPeriod(1000)

    fmt.Print("Press enter to exit.")
    fmt.Scanln()
}

Threshold

Download (example_threshold.go)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
package main

import (
    "fmt"
    "github.com/Tinkerforge/go-api-bindings/ipconnection"
    "github.com/Tinkerforge/go-api-bindings/moisture_bricklet"
)

const ADDR string = "localhost:4223"
const UID string = "XYZ" // Change XYZ to the UID of your Moisture Bricklet.

func main() {
    ipcon := ipconnection.New()
    defer ipcon.Close()
    m, _ := moisture_bricklet.New(UID, &ipcon) // Create device object.

    ipcon.Connect(ADDR) // Connect to brickd.
    defer ipcon.Disconnect()
    // Don't use device before ipcon is connected.

    // Get threshold receivers with a debounce time of 1 second (1000ms).
    m.SetDebouncePeriod(1000)

    m.RegisterMoistureReachedCallback(func(moisture uint16) {
        fmt.Printf("Moisture Value: %d\n", moisture)
    })

    // Configure threshold for moisture value "greater than 200".
    m.SetMoistureCallbackThreshold('>', 200, 0)

    fmt.Print("Press enter to exit.")
    fmt.Scanln()
}

API

The Moisture Bricklet API is defined in the package github.com/Tinkerforge/go-api-bindings/moisture_bricklet

Nearly every function of the Go bindings can return an DeviceError, implementing the error interface. The error can have one of the following values:

  • DeviceErrorSuccess = 0
  • DeviceErrorInvalidParameter = 1
  • DeviceErrorFunctionNotSupported = 2
  • DeviceErrorUnknownError = 3

which correspond to the values returned from Bricks and Bricklets.

All functions listed below are thread-safe.

Basic Functions

func moisture_bricklet.New(uid string, ipcon *IPConnection) (device MoistureBricklet, err error)

Creates a new MoistureBricklet object with the unique device ID uid and adds it to the IPConnection ipcon:

device, err := moisture_bricklet.New("YOUR_DEVICE_UID", &ipcon)

This device object can be used after the IPConnection has been connected (see examples above).

func (*MoistureBricklet) GetMoistureValue() (moisture uint16, err error)

Returns the current moisture value. The value has a range of 0 to 4095. A small value corresponds to little moisture, a big value corresponds to much moisture.

If you want to get the moisture value periodically, it is recommended to use the RegisterMoistureCallback callback and set the period with SetMoistureCallbackPeriod().

Advanced Functions

func (*MoistureBricklet) SetMovingAverage(average uint8) (err error)

Sets the length of a moving averaging for the moisture value.

Setting the length to 0 will turn the averaging completely off. With less averaging, there is more noise on the data.

The range for the averaging is 0-100.

The default value is 100.

func (*MoistureBricklet) GetMovingAverage() (average uint8, err error)

Returns the length moving average as set by SetMovingAverage().

func (*MoistureBricklet) GetAPIVersion() (apiVersion [3]uint8, err error)

Returns the version of the API definition (major, minor, revision) implemented by this API bindings. This is neither the release version of this API bindings nor does it tell you anything about the represented Brick or Bricklet.

func (*MoistureBricklet) GetResponseExpected(functionId Function) (responseExpected bool, err error)

Returns the response expected flag for the function specified by the function ID parameter. It is true if the function is expected to send a response, false otherwise.

For getter functions this is enabled by default and cannot be disabled, because those functions will always send a response. For callback configuration functions it is enabled by default too, but can be disabled by SetResponseExpected(). For setter functions it is disabled by default and can be enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is send and errors are silently ignored, because they cannot be detected.

The following constants are available for this function:

  • moisture_bricklet.FunctionSetMoistureCallbackPeriod = 2
  • moisture_bricklet.FunctionSetMoistureCallbackThreshold = 4
  • moisture_bricklet.FunctionSetDebouncePeriod = 6
  • moisture_bricklet.FunctionSetMovingAverage = 10
func (*MoistureBricklet) SetResponseExpected(functionId Function, responseExpected bool) (err error)

Changes the response expected flag of the function specified by the function ID parameter. This flag can only be changed for setter (default value: false) and callback configuration functions (default value: true). For getter functions it is always enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is send and errors are silently ignored, because they cannot be detected.

The following constants are available for this function:

  • moisture_bricklet.FunctionSetMoistureCallbackPeriod = 2
  • moisture_bricklet.FunctionSetMoistureCallbackThreshold = 4
  • moisture_bricklet.FunctionSetDebouncePeriod = 6
  • moisture_bricklet.FunctionSetMovingAverage = 10
func (*MoistureBricklet) SetResponseExpectedAll(responseExpected bool) (err error)

Changes the response expected flag for all setter and callback configuration functions of this device at once.

func (*MoistureBricklet) GetIdentity() (uid string, connectedUid string, position rune, hardwareVersion [3]uint8, firmwareVersion [3]uint8, deviceIdentifier uint16, err error)

Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.

The position can be 'a', 'b', 'c' or 'd'.

The device identifier numbers can be found here. There is also a constant for the device identifier of this Bricklet.

Callback Configuration Functions

func (*MoistureBricklet) SetMoistureCallbackPeriod(period uint32) (err error)

Sets the period in ms with which the RegisterMoistureCallback callback is triggered periodically. A value of 0 turns the callback off.

The RegisterMoistureCallback callback is only triggered if the moisture value has changed since the last triggering.

The default value is 0.

func (*MoistureBricklet) GetMoistureCallbackPeriod() (period uint32, err error)

Returns the period as set by SetMoistureCallbackPeriod().

func (*MoistureBricklet) SetMoistureCallbackThreshold(option ThresholdOption, min uint16, max uint16) (err error)

Sets the thresholds for the RegisterMoistureReachedCallback callback.

The following options are possible:

Option Description
'x' Callback is turned off
'o' Callback is triggered when the moisture value is outside the min and max values
'i' Callback is triggered when the moisture value is inside the min and max values
'<' Callback is triggered when the moisture value is smaller than the min value (max is ignored)
'>' Callback is triggered when the moisture value is greater than the min value (max is ignored)

The default value is ('x', 0, 0).

The following constants are available for this function:

  • moisture_bricklet.ThresholdOptionOff = 'x'
  • moisture_bricklet.ThresholdOptionOutside = 'o'
  • moisture_bricklet.ThresholdOptionInside = 'i'
  • moisture_bricklet.ThresholdOptionSmaller = '<'
  • moisture_bricklet.ThresholdOptionGreater = '>'
func (*MoistureBricklet) GetMoistureCallbackThreshold() (option ThresholdOption, min uint16, max uint16, err error)

Returns the threshold as set by SetMoistureCallbackThreshold().

The following constants are available for this function:

  • moisture_bricklet.ThresholdOptionOff = 'x'
  • moisture_bricklet.ThresholdOptionOutside = 'o'
  • moisture_bricklet.ThresholdOptionInside = 'i'
  • moisture_bricklet.ThresholdOptionSmaller = '<'
  • moisture_bricklet.ThresholdOptionGreater = '>'
func (*MoistureBricklet) SetDebouncePeriod(debounce uint32) (err error)

Sets the period in ms with which the threshold callback

is triggered, if the threshold

keeps being reached.

The default value is 100.

func (*MoistureBricklet) GetDebouncePeriod() (debounce uint32, err error)

Returns the debounce period as set by SetDebouncePeriod().

Callbacks

Callbacks can be registered to receive time critical or recurring data from the device. The registration is done with the corresponding Register*Callback function, which returns a unique callback ID. This ID can be used to deregister the callback later.

Note

Using callbacks for recurring events is always preferred compared to using getters. It will use less USB bandwidth and the latency will be a lot better, since there is no round trip time.

func (*MoistureBricklet) RegisterMoistureCallback(func(moisture uint16)) (registrationId uint64)

A callback can be registered for this event with the RegisterMoistureCallback() function. This function returns the ID of the registered callback. An added callback can be removed with the DeregisterMoistureCallback(registrationId uint64) function.

This callback is triggered periodically with the period that is set by SetMoistureCallbackPeriod(). The callback parameter is the moisture value of the sensor.

The RegisterMoistureCallback callback is only triggered if the moisture value has changed since the last triggering.

func (*MoistureBricklet) RegisterMoistureReachedCallback(func(moisture uint16)) (registrationId uint64)

A callback can be registered for this event with the RegisterMoistureReachedCallback() function. This function returns the ID of the registered callback. An added callback can be removed with the DeregisterMoistureReachedCallback(registrationId uint64) function.

This callback is triggered when the threshold as set by SetMoistureCallbackThreshold() is reached. The callback parameter is the moisture value of the sensor.

If the threshold keeps being reached, the callback is triggered periodically with the period as set by SetDebouncePeriod().

Constants

moisture_bricklet.DeviceIdentifier

This constant is used to identify a Moisture Bricklet.

The GetIdentity() function and the (*IPConnection) RegisterEnumerateCallback callback of the IPConnection have a deviceIdentifier parameter to specify the Brick's or Bricklet's type.

moisture_bricklet.DeviceDisplayName

This constant represents the human readable name of a Moisture Bricklet.