Java - UV Light Bricklet 2.0

This is the description of the Java API bindings for the UV Light Bricklet 2.0. General information and technical specifications for the UV Light Bricklet 2.0 are summarized in its hardware description.

An installation guide for the Java API bindings is part of their general description.

Examples

The example code below is Public Domain (CC0 1.0).

Callback

Download (ExampleCallback.java)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
import com.tinkerforge.IPConnection;
import com.tinkerforge.BrickletUVLightV2;

public class ExampleCallback {
    private static final String HOST = "localhost";
    private static final int PORT = 4223;

    // Change XYZ to the UID of your UV Light Bricklet 2.0
    private static final String UID = "XYZ";

    // Note: To make the example code cleaner we do not handle exceptions. Exceptions
    //       you might normally want to catch are described in the documentation
    public static void main(String args[]) throws Exception {
        IPConnection ipcon = new IPConnection(); // Create IP connection
        BrickletUVLightV2 uvl = new BrickletUVLightV2(UID, ipcon); // Create device object

        ipcon.connect(HOST, PORT); // Connect to brickd
        // Don't use device before ipcon is connected

        // Add UV index listener
        uvl.addUVIListener(new BrickletUVLightV2.UVIListener() {
            public void uvi(int uvi) {
                System.out.println("UV Index: " + uvi/10.0);
            }
        });

        // Set period for UVI callback to 1s (1000ms) without a threshold
        uvl.setUVICallbackConfiguration(1000, false, 'x', 0, 0);

        System.out.println("Press key to exit"); System.in.read();
        ipcon.disconnect();
    }
}

Simple

Download (ExampleSimple.java)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
import com.tinkerforge.IPConnection;
import com.tinkerforge.BrickletUVLightV2;

public class ExampleSimple {
    private static final String HOST = "localhost";
    private static final int PORT = 4223;

    // Change XYZ to the UID of your UV Light Bricklet 2.0
    private static final String UID = "XYZ";

    // Note: To make the example code cleaner we do not handle exceptions. Exceptions
    //       you might normally want to catch are described in the documentation
    public static void main(String args[]) throws Exception {
        IPConnection ipcon = new IPConnection(); // Create IP connection
        BrickletUVLightV2 uvl = new BrickletUVLightV2(UID, ipcon); // Create device object

        ipcon.connect(HOST, PORT); // Connect to brickd
        // Don't use device before ipcon is connected

        // Get current UV-A
        int uva = uvl.getUVA(); // Can throw com.tinkerforge.TimeoutException
        System.out.println("UV-A: " + uva/10.0 + " mW/m²");

        // Get current UV-B
        int uvb = uvl.getUVB(); // Can throw com.tinkerforge.TimeoutException
        System.out.println("UV-B: " + uvb/10.0 + " mW/m²");

        // Get current UV index
        int uvi = uvl.getUVI(); // Can throw com.tinkerforge.TimeoutException
        System.out.println("UV Index: " + uvi/10.0);

        System.out.println("Press key to exit"); System.in.read();
        ipcon.disconnect();
    }
}

Threshold

Download (ExampleThreshold.java)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
import com.tinkerforge.IPConnection;
import com.tinkerforge.BrickletUVLightV2;

public class ExampleThreshold {
    private static final String HOST = "localhost";
    private static final int PORT = 4223;

    // Change XYZ to the UID of your UV Light Bricklet 2.0
    private static final String UID = "XYZ";

    // Note: To make the example code cleaner we do not handle exceptions. Exceptions
    //       you might normally want to catch are described in the documentation
    public static void main(String args[]) throws Exception {
        IPConnection ipcon = new IPConnection(); // Create IP connection
        BrickletUVLightV2 uvl = new BrickletUVLightV2(UID, ipcon); // Create device object

        ipcon.connect(HOST, PORT); // Connect to brickd
        // Don't use device before ipcon is connected

        // Add UV index listener
        uvl.addUVIListener(new BrickletUVLightV2.UVIListener() {
            public void uvi(int uvi) {
                System.out.println("UV Index: " + uvi/10.0);
                System.out.println("UV index > 3. Use sunscreen!");
            }
        });

        // Configure threshold for UV index "greater than 3"
        // with a debounce period of 1s (1000ms)
        uvl.setUVICallbackConfiguration(1000, false, '>', 3*10, 0);

        System.out.println("Press key to exit"); System.in.read();
        ipcon.disconnect();
    }
}

API

Generally, every method of the Java bindings that returns a value can throw a TimeoutException. This exception gets thrown if the device did not respond. If a cable based connection is used, it is unlikely that this exception gets thrown (assuming nobody unplugs the device). However, if a wireless connection is used, timeouts will occur if the distance to the device gets too big.

Beside the TimeoutException there is also a NotConnectedException that is thrown if a method needs to communicate with the device while the IP Connection is not connected.

Since Java does not support multiple return values and return by reference is not possible for primitive types, we use small classes that only consist of member variables. The member variables of the returned objects are described in the corresponding method descriptions.

The package for all Brick/Bricklet bindings and the IP Connection is com.tinkerforge.*

All methods listed below are thread-safe.

Basic Functions

class BrickletUVLightV2(String uid, IPConnection ipcon)
Parameters:
  • uid – Type: String
  • ipcon – Type: IPConnection
Returns:
  • uvLightV2 – Type: BrickletUVLightV2

Creates an object with the unique device ID uid:

BrickletUVLightV2 uvLightV2 = new BrickletUVLightV2("YOUR_DEVICE_UID", ipcon);

This object can then be used after the IP Connection is connected.

int BrickletUVLightV2.getUVA()
Returns:
  • uva – Type: int, Unit: 1/10 mW/m², Range: [-1 to 231 - 1]

Returns the UVA intensity of the sensor. The sensor has not weighted the intensity with the erythemal action spectrum to get the skin-affecting irradiation. Therefore, you cannot just divide the value by 250 to get the UVA index. To get the UV index use getUVI().

If the sensor is saturated, then -1 is returned, see setConfiguration().

If you want to get the intensity periodically, it is recommended to use the UVAListener listener and set the period with setUVACallbackConfiguration().

If you want to get the value periodically, it is recommended to use the UVAListener listener. You can set the listener configuration with setUVACallbackConfiguration().

int BrickletUVLightV2.getUVB()
Returns:
  • uvb – Type: int, Unit: 1/10 mW/m², Range: [-1 to 231 - 1]

Returns the UVB intensity of the sensor. The sensor has not weighted the intensity with the erythemal action spectrum to get the skin-affecting irradiation. Therefore, you cannot just divide the value by 250 to get the UVB index. To get the UV index use getUVI().

If the sensor is saturated, then -1 is returned, see setConfiguration().

If you want to get the intensity periodically, it is recommended to use the UVBListener listener and set the period with setUVBCallbackConfiguration().

If you want to get the value periodically, it is recommended to use the UVBListener listener. You can set the listener configuration with setUVBCallbackConfiguration().

int BrickletUVLightV2.getUVI()
Returns:
  • uvi – Type: int, Unit: 1/10 , Range: [-1 to 231 - 1]

Returns the UV index of the sensor, the index is given in 1/10.

If the sensor is saturated, then -1 is returned, see setConfiguration().

If you want to get the intensity periodically, it is recommended to use the UVIListener listener and set the period with setUVICallbackConfiguration().

If you want to get the value periodically, it is recommended to use the UVIListener listener. You can set the listener configuration with setUVICallbackConfiguration().

Advanced Functions

void BrickletUVLightV2.setConfiguration(int integrationTime)
Parameters:
  • integrationTime – Type: int, Range: See constants, Default: 3

Sets the configuration of the sensor. The integration time can be configured between 50 and 800 ms. With a shorter integration time the sensor reading updates more often but contains more noise. With a longer integration the sensor reading contains less noise but updates less often.

With a longer integration time (especially 800 ms) and a higher UV intensity the sensor can be saturated. If this happens the UVA/UVB/UVI readings are all -1. In this case you need to choose a shorter integration time.

The following constants are available for this function:

For integrationTime:

  • BrickletUVLightV2.INTEGRATION_TIME_50MS = 0
  • BrickletUVLightV2.INTEGRATION_TIME_100MS = 1
  • BrickletUVLightV2.INTEGRATION_TIME_200MS = 2
  • BrickletUVLightV2.INTEGRATION_TIME_400MS = 3
  • BrickletUVLightV2.INTEGRATION_TIME_800MS = 4
int BrickletUVLightV2.getConfiguration()
Returns:
  • integrationTime – Type: int, Range: See constants, Default: 3

Returns the configuration as set by setConfiguration().

The following constants are available for this function:

For integrationTime:

  • BrickletUVLightV2.INTEGRATION_TIME_50MS = 0
  • BrickletUVLightV2.INTEGRATION_TIME_100MS = 1
  • BrickletUVLightV2.INTEGRATION_TIME_200MS = 2
  • BrickletUVLightV2.INTEGRATION_TIME_400MS = 3
  • BrickletUVLightV2.INTEGRATION_TIME_800MS = 4
BrickletUVLightV2.SPITFPErrorCount BrickletUVLightV2.getSPITFPErrorCount()
Return Object:
  • errorCountAckChecksum – Type: long, Range: [0 to 232 - 1]
  • errorCountMessageChecksum – Type: long, Range: [0 to 232 - 1]
  • errorCountFrame – Type: long, Range: [0 to 232 - 1]
  • errorCountOverflow – Type: long, Range: [0 to 232 - 1]

Returns the error count for the communication between Brick and Bricklet.

The errors are divided into

  • ACK checksum errors,
  • message checksum errors,
  • framing errors and
  • overflow errors.

The errors counts are for errors that occur on the Bricklet side. All Bricks have a similar function that returns the errors on the Brick side.

void BrickletUVLightV2.setStatusLEDConfig(int config)
Parameters:
  • config – Type: int, Range: See constants, Default: 3

Sets the status LED configuration. By default the LED shows communication traffic between Brick and Bricklet, it flickers once for every 10 received data packets.

You can also turn the LED permanently on/off or show a heartbeat.

If the Bricklet is in bootloader mode, the LED is will show heartbeat by default.

The following constants are available for this function:

For config:

  • BrickletUVLightV2.STATUS_LED_CONFIG_OFF = 0
  • BrickletUVLightV2.STATUS_LED_CONFIG_ON = 1
  • BrickletUVLightV2.STATUS_LED_CONFIG_SHOW_HEARTBEAT = 2
  • BrickletUVLightV2.STATUS_LED_CONFIG_SHOW_STATUS = 3
int BrickletUVLightV2.getStatusLEDConfig()
Returns:
  • config – Type: int, Range: See constants, Default: 3

Returns the configuration as set by setStatusLEDConfig()

The following constants are available for this function:

For config:

  • BrickletUVLightV2.STATUS_LED_CONFIG_OFF = 0
  • BrickletUVLightV2.STATUS_LED_CONFIG_ON = 1
  • BrickletUVLightV2.STATUS_LED_CONFIG_SHOW_HEARTBEAT = 2
  • BrickletUVLightV2.STATUS_LED_CONFIG_SHOW_STATUS = 3
int BrickletUVLightV2.getChipTemperature()
Returns:
  • temperature – Type: int, Unit: 1 °C, Range: [-215 to 215 - 1]

Returns the temperature as measured inside the microcontroller. The value returned is not the ambient temperature!

The temperature is only proportional to the real temperature and it has bad accuracy. Practically it is only useful as an indicator for temperature changes.

void BrickletUVLightV2.reset()

Calling this function will reset the Bricklet. All configurations will be lost.

After a reset you have to create new device objects, calling functions on the existing ones will result in undefined behavior!

BrickletUVLightV2.Identity BrickletUVLightV2.getIdentity()
Return Object:
  • uid – Type: String, Length: up to 8
  • connectedUid – Type: String, Length: up to 8
  • position – Type: char, Range: ['a' to 'h', 'z']
  • hardwareVersion – Type: short[], Length: 3
    • 0: major – Type: short, Range: [0 to 255]
    • 1: minor – Type: short, Range: [0 to 255]
    • 2: revision – Type: short, Range: [0 to 255]
  • firmwareVersion – Type: short[], Length: 3
    • 0: major – Type: short, Range: [0 to 255]
    • 1: minor – Type: short, Range: [0 to 255]
    • 2: revision – Type: short, Range: [0 to 255]
  • deviceIdentifier – Type: int, Range: [0 to 216 - 1]

Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.

The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an Isolator Bricklet is always at position 'z'.

The device identifier numbers can be found here. There is also a constant for the device identifier of this Bricklet.

Listener Configuration Functions

void BrickletUVLightV2.setUVACallbackConfiguration(long period, boolean valueHasToChange, char option, int min, int max)
Parameters:
  • period – Type: long, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • valueHasToChange – Type: boolean, Default: false
  • option – Type: char, Range: See constants, Default: 'x'
  • min – Type: int, Unit: 1/10 mW/m², Range: [-231 to 231 - 1], Default: 0
  • max – Type: int, Unit: 1/10 mW/m², Range: [-231 to 231 - 1], Default: 0

The period is the period with which the UVAListener listener is triggered periodically. A value of 0 turns the listener off.

If the value has to change-parameter is set to true, the listener is only triggered after the value has changed. If the value didn't change within the period, the listener is triggered immediately on change.

If it is set to false, the listener is continuously triggered with the period, independent of the value.

It is furthermore possible to constrain the listener with thresholds.

The option-parameter together with min/max sets a threshold for the UVAListener listener.

The following options are possible:

Option Description
'x' Threshold is turned off
'o' Threshold is triggered when the value is outside the min and max values
'i' Threshold is triggered when the value is inside or equal to the min and max values
'<' Threshold is triggered when the value is smaller than the min value (max is ignored)
'>' Threshold is triggered when the value is greater than the min value (max is ignored)

If the option is set to 'x' (threshold turned off) the listener is triggered with the fixed period.

The following constants are available for this function:

For option:

  • BrickletUVLightV2.THRESHOLD_OPTION_OFF = 'x'
  • BrickletUVLightV2.THRESHOLD_OPTION_OUTSIDE = 'o'
  • BrickletUVLightV2.THRESHOLD_OPTION_INSIDE = 'i'
  • BrickletUVLightV2.THRESHOLD_OPTION_SMALLER = '<'
  • BrickletUVLightV2.THRESHOLD_OPTION_GREATER = '>'
BrickletUVLightV2.UVACallbackConfiguration BrickletUVLightV2.getUVACallbackConfiguration()
Return Object:
  • period – Type: long, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • valueHasToChange – Type: boolean, Default: false
  • option – Type: char, Range: See constants, Default: 'x'
  • min – Type: int, Unit: 1/10 mW/m², Range: [-231 to 231 - 1], Default: 0
  • max – Type: int, Unit: 1/10 mW/m², Range: [-231 to 231 - 1], Default: 0

Returns the listener configuration as set by setUVACallbackConfiguration().

The following constants are available for this function:

For option:

  • BrickletUVLightV2.THRESHOLD_OPTION_OFF = 'x'
  • BrickletUVLightV2.THRESHOLD_OPTION_OUTSIDE = 'o'
  • BrickletUVLightV2.THRESHOLD_OPTION_INSIDE = 'i'
  • BrickletUVLightV2.THRESHOLD_OPTION_SMALLER = '<'
  • BrickletUVLightV2.THRESHOLD_OPTION_GREATER = '>'
void BrickletUVLightV2.setUVBCallbackConfiguration(long period, boolean valueHasToChange, char option, int min, int max)
Parameters:
  • period – Type: long, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • valueHasToChange – Type: boolean, Default: false
  • option – Type: char, Range: See constants, Default: 'x'
  • min – Type: int, Unit: 1/10 mW/m², Range: [-231 to 231 - 1], Default: 0
  • max – Type: int, Unit: 1/10 mW/m², Range: [-231 to 231 - 1], Default: 0

The period is the period with which the UVBListener listener is triggered periodically. A value of 0 turns the listener off.

If the value has to change-parameter is set to true, the listener is only triggered after the value has changed. If the value didn't change within the period, the listener is triggered immediately on change.

If it is set to false, the listener is continuously triggered with the period, independent of the value.

It is furthermore possible to constrain the listener with thresholds.

The option-parameter together with min/max sets a threshold for the UVBListener listener.

The following options are possible:

Option Description
'x' Threshold is turned off
'o' Threshold is triggered when the value is outside the min and max values
'i' Threshold is triggered when the value is inside or equal to the min and max values
'<' Threshold is triggered when the value is smaller than the min value (max is ignored)
'>' Threshold is triggered when the value is greater than the min value (max is ignored)

If the option is set to 'x' (threshold turned off) the listener is triggered with the fixed period.

The following constants are available for this function:

For option:

  • BrickletUVLightV2.THRESHOLD_OPTION_OFF = 'x'
  • BrickletUVLightV2.THRESHOLD_OPTION_OUTSIDE = 'o'
  • BrickletUVLightV2.THRESHOLD_OPTION_INSIDE = 'i'
  • BrickletUVLightV2.THRESHOLD_OPTION_SMALLER = '<'
  • BrickletUVLightV2.THRESHOLD_OPTION_GREATER = '>'
BrickletUVLightV2.UVBCallbackConfiguration BrickletUVLightV2.getUVBCallbackConfiguration()
Return Object:
  • period – Type: long, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • valueHasToChange – Type: boolean, Default: false
  • option – Type: char, Range: See constants, Default: 'x'
  • min – Type: int, Unit: 1/10 mW/m², Range: [-231 to 231 - 1], Default: 0
  • max – Type: int, Unit: 1/10 mW/m², Range: [-231 to 231 - 1], Default: 0

Returns the listener configuration as set by setUVBCallbackConfiguration().

The following constants are available for this function:

For option:

  • BrickletUVLightV2.THRESHOLD_OPTION_OFF = 'x'
  • BrickletUVLightV2.THRESHOLD_OPTION_OUTSIDE = 'o'
  • BrickletUVLightV2.THRESHOLD_OPTION_INSIDE = 'i'
  • BrickletUVLightV2.THRESHOLD_OPTION_SMALLER = '<'
  • BrickletUVLightV2.THRESHOLD_OPTION_GREATER = '>'
void BrickletUVLightV2.setUVICallbackConfiguration(long period, boolean valueHasToChange, char option, int min, int max)
Parameters:
  • period – Type: long, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • valueHasToChange – Type: boolean, Default: false
  • option – Type: char, Range: See constants, Default: 'x'
  • min – Type: int, Unit: 1/10 , Range: [-231 to 231 - 1], Default: 0
  • max – Type: int, Unit: 1/10 , Range: [-231 to 231 - 1], Default: 0

The period is the period with which the UVIListener listener is triggered periodically. A value of 0 turns the listener off.

If the value has to change-parameter is set to true, the listener is only triggered after the value has changed. If the value didn't change within the period, the listener is triggered immediately on change.

If it is set to false, the listener is continuously triggered with the period, independent of the value.

It is furthermore possible to constrain the listener with thresholds.

The option-parameter together with min/max sets a threshold for the UVIListener listener.

The following options are possible:

Option Description
'x' Threshold is turned off
'o' Threshold is triggered when the value is outside the min and max values
'i' Threshold is triggered when the value is inside or equal to the min and max values
'<' Threshold is triggered when the value is smaller than the min value (max is ignored)
'>' Threshold is triggered when the value is greater than the min value (max is ignored)

If the option is set to 'x' (threshold turned off) the listener is triggered with the fixed period.

The following constants are available for this function:

For option:

  • BrickletUVLightV2.THRESHOLD_OPTION_OFF = 'x'
  • BrickletUVLightV2.THRESHOLD_OPTION_OUTSIDE = 'o'
  • BrickletUVLightV2.THRESHOLD_OPTION_INSIDE = 'i'
  • BrickletUVLightV2.THRESHOLD_OPTION_SMALLER = '<'
  • BrickletUVLightV2.THRESHOLD_OPTION_GREATER = '>'
BrickletUVLightV2.UVICallbackConfiguration BrickletUVLightV2.getUVICallbackConfiguration()
Return Object:
  • period – Type: long, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • valueHasToChange – Type: boolean, Default: false
  • option – Type: char, Range: See constants, Default: 'x'
  • min – Type: int, Unit: 1/10 , Range: [-231 to 231 - 1], Default: 0
  • max – Type: int, Unit: 1/10 , Range: [-231 to 231 - 1], Default: 0

Returns the listener configuration as set by setUVICallbackConfiguration().

The following constants are available for this function:

For option:

  • BrickletUVLightV2.THRESHOLD_OPTION_OFF = 'x'
  • BrickletUVLightV2.THRESHOLD_OPTION_OUTSIDE = 'o'
  • BrickletUVLightV2.THRESHOLD_OPTION_INSIDE = 'i'
  • BrickletUVLightV2.THRESHOLD_OPTION_SMALLER = '<'
  • BrickletUVLightV2.THRESHOLD_OPTION_GREATER = '>'

Listeners

Listeners can be registered to receive time critical or recurring data from the device. The registration is done with add*Listener() functions of the device object.

The parameter is a listener class object, for example:

device.addExampleListener(new BrickletUVLightV2.ExampleListener() {
    public void property(int value) {
        System.out.println("Value: " + value);
    }
});

The available listener classes with inherent methods to be overwritten are described below. It is possible to add several listeners and to remove them with the corresponding remove*Listener() function.

Note

Using listeners for recurring events is always preferred compared to using getters. It will use less USB bandwidth and the latency will be a lot better, since there is no round trip time.

class BrickletUVLightV2.UVAListener()

This listener can be added with the addUVAListener() function. An added listener can be removed with the removeUVAListener() function.

void uva(int uva)
Parameters:
  • uva – Type: int, Unit: 1/10 mW/m², Range: [-1 to 231 - 1]

This listener is triggered periodically according to the configuration set by setUVACallbackConfiguration().

The parameter is the same as getUVA().

class BrickletUVLightV2.UVBListener()

This listener can be added with the addUVBListener() function. An added listener can be removed with the removeUVBListener() function.

void uvb(int uvb)
Parameters:
  • uvb – Type: int, Unit: 1/10 mW/m², Range: [-1 to 231 - 1]

This listener is triggered periodically according to the configuration set by setUVBCallbackConfiguration().

The parameter is the same as getUVB().

class BrickletUVLightV2.UVIListener()

This listener can be added with the addUVIListener() function. An added listener can be removed with the removeUVIListener() function.

void uvi(int uvi)
Parameters:
  • uvi – Type: int, Unit: 1/10 , Range: [-1 to 231 - 1]

This listener is triggered periodically according to the configuration set by setUVICallbackConfiguration().

The parameter is the same as getUVI().

Virtual Functions

Virtual functions don't communicate with the device itself, but operate only on the API bindings device object. They can be called without the corresponding IP Connection object being connected.

short[] BrickletUVLightV2.getAPIVersion()
Return Object:
  • apiVersion – Type: short[], Length: 3
    • 0: major – Type: short, Range: [0 to 255]
    • 1: minor – Type: short, Range: [0 to 255]
    • 2: revision – Type: short, Range: [0 to 255]

Returns the version of the API definition implemented by this API bindings. This is neither the release version of this API bindings nor does it tell you anything about the represented Brick or Bricklet.

boolean BrickletUVLightV2.getResponseExpected(byte functionId)
Parameters:
  • functionId – Type: byte, Range: See constants
Returns:
  • responseExpected – Type: boolean

Returns the response expected flag for the function specified by the function ID parameter. It is true if the function is expected to send a response, false otherwise.

For getter functions this is enabled by default and cannot be disabled, because those functions will always send a response. For listener configuration functions it is enabled by default too, but can be disabled by setResponseExpected(). For setter functions it is disabled by default and can be enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.

The following constants are available for this function:

For functionId:

  • BrickletUVLightV2.FUNCTION_SET_UVA_CALLBACK_CONFIGURATION = 2
  • BrickletUVLightV2.FUNCTION_SET_UVB_CALLBACK_CONFIGURATION = 6
  • BrickletUVLightV2.FUNCTION_SET_UVI_CALLBACK_CONFIGURATION = 10
  • BrickletUVLightV2.FUNCTION_SET_CONFIGURATION = 13
  • BrickletUVLightV2.FUNCTION_SET_WRITE_FIRMWARE_POINTER = 237
  • BrickletUVLightV2.FUNCTION_SET_STATUS_LED_CONFIG = 239
  • BrickletUVLightV2.FUNCTION_RESET = 243
  • BrickletUVLightV2.FUNCTION_WRITE_UID = 248
void BrickletUVLightV2.setResponseExpected(byte functionId, boolean responseExpected)
Parameters:
  • functionId – Type: byte, Range: See constants
  • responseExpected – Type: boolean

Changes the response expected flag of the function specified by the function ID parameter. This flag can only be changed for setter (default value: false) and listener configuration functions (default value: true). For getter functions it is always enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.

The following constants are available for this function:

For functionId:

  • BrickletUVLightV2.FUNCTION_SET_UVA_CALLBACK_CONFIGURATION = 2
  • BrickletUVLightV2.FUNCTION_SET_UVB_CALLBACK_CONFIGURATION = 6
  • BrickletUVLightV2.FUNCTION_SET_UVI_CALLBACK_CONFIGURATION = 10
  • BrickletUVLightV2.FUNCTION_SET_CONFIGURATION = 13
  • BrickletUVLightV2.FUNCTION_SET_WRITE_FIRMWARE_POINTER = 237
  • BrickletUVLightV2.FUNCTION_SET_STATUS_LED_CONFIG = 239
  • BrickletUVLightV2.FUNCTION_RESET = 243
  • BrickletUVLightV2.FUNCTION_WRITE_UID = 248
void BrickletUVLightV2.setResponseExpectedAll(boolean responseExpected)
Parameters:
  • responseExpected – Type: boolean

Changes the response expected flag for all setter and listener configuration functions of this device at once.

Internal Functions

Internal functions are used for maintenance tasks such as flashing a new firmware of changing the UID of a Bricklet. These task should be performed using Brick Viewer instead of using the internal functions directly.

int BrickletUVLightV2.setBootloaderMode(int mode)
Parameters:
  • mode – Type: int, Range: See constants
Returns:
  • status – Type: int, Range: See constants

Sets the bootloader mode and returns the status after the requested mode change was instigated.

You can change from bootloader mode to firmware mode and vice versa. A change from bootloader mode to firmware mode will only take place if the entry function, device identifier and CRC are present and correct.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

The following constants are available for this function:

For mode:

  • BrickletUVLightV2.BOOTLOADER_MODE_BOOTLOADER = 0
  • BrickletUVLightV2.BOOTLOADER_MODE_FIRMWARE = 1
  • BrickletUVLightV2.BOOTLOADER_MODE_BOOTLOADER_WAIT_FOR_REBOOT = 2
  • BrickletUVLightV2.BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_REBOOT = 3
  • BrickletUVLightV2.BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_ERASE_AND_REBOOT = 4

For status:

  • BrickletUVLightV2.BOOTLOADER_STATUS_OK = 0
  • BrickletUVLightV2.BOOTLOADER_STATUS_INVALID_MODE = 1
  • BrickletUVLightV2.BOOTLOADER_STATUS_NO_CHANGE = 2
  • BrickletUVLightV2.BOOTLOADER_STATUS_ENTRY_FUNCTION_NOT_PRESENT = 3
  • BrickletUVLightV2.BOOTLOADER_STATUS_DEVICE_IDENTIFIER_INCORRECT = 4
  • BrickletUVLightV2.BOOTLOADER_STATUS_CRC_MISMATCH = 5
int BrickletUVLightV2.getBootloaderMode()
Returns:
  • mode – Type: int, Range: See constants

Returns the current bootloader mode, see setBootloaderMode().

The following constants are available for this function:

For mode:

  • BrickletUVLightV2.BOOTLOADER_MODE_BOOTLOADER = 0
  • BrickletUVLightV2.BOOTLOADER_MODE_FIRMWARE = 1
  • BrickletUVLightV2.BOOTLOADER_MODE_BOOTLOADER_WAIT_FOR_REBOOT = 2
  • BrickletUVLightV2.BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_REBOOT = 3
  • BrickletUVLightV2.BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_ERASE_AND_REBOOT = 4
void BrickletUVLightV2.setWriteFirmwarePointer(long pointer)
Parameters:
  • pointer – Type: long, Unit: 1 B, Range: [0 to 232 - 1]

Sets the firmware pointer for writeFirmware(). The pointer has to be increased by chunks of size 64. The data is written to flash every 4 chunks (which equals to one page of size 256).

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

int BrickletUVLightV2.writeFirmware(int[] data)
Parameters:
  • data – Type: int[], Length: 64, Range: [0 to 255]
Returns:
  • status – Type: int, Range: [0 to 255]

Writes 64 Bytes of firmware at the position as written by setWriteFirmwarePointer() before. The firmware is written to flash every 4 chunks.

You can only write firmware in bootloader mode.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

void BrickletUVLightV2.writeUID(long uid)
Parameters:
  • uid – Type: long, Range: [0 to 232 - 1]

Writes a new UID into flash. If you want to set a new UID you have to decode the Base58 encoded UID string into an integer first.

We recommend that you use Brick Viewer to change the UID.

long BrickletUVLightV2.readUID()
Returns:
  • uid – Type: long, Range: [0 to 232 - 1]

Returns the current UID as an integer. Encode as Base58 to get the usual string version.

Constants

int BrickletUVLightV2.DEVICE_IDENTIFIER

This constant is used to identify a UV Light Bricklet 2.0.

The getIdentity() function and the IPConnection.EnumerateListener listener of the IP Connection have a deviceIdentifier parameter to specify the Brick's or Bricklet's type.

String BrickletUVLightV2.DEVICE_DISPLAY_NAME

This constant represents the human readable name of a UV Light Bricklet 2.0.